Using the bodypack transmitter

￿ Press the SET button.

The lock mode is temporarily deactivated.

How you are using the bodypack transmitter determines how long the lock mode remains deactivated:

When you are in the operating menu

The lock mode remains deactivated until you exit the operating menu.

When one of the standard displays is shown

The lock mode is automatically activated after 10 seconds.

The lock mode icon ￿ flashes prior to the lock mode being activated again.

531.375MHz ew300 G3 ￿

AF P MUTE

Muting the audio signal or deactivating the RF signal

￿

The MUTE switch ￿ allows you to mute the audio signal or to deactivate the RF signal.

Via the “Mute Mode” menu item, you can set the desired function of the MUTE switch ￿ (see page 24):

 

Slide the MUTE

 

Setting

switch ￿ ...

Function

 

 

 

AF On/Off

... to the left

Mutes the audio signal

 

(position MUTE)

 

 

... to the right

Unmutes the audio

 

 

signal

 

 

 

RF On/Off

... to the left

Deactivates the RF

 

(position MUTE)

signal

 

 

(offline operation)

 

... to the right

Activates the RF signal

 

 

(online operation)

Disabled

No function

 

 

 

 

￿From the “Mute Mode” menu item, select the desired setting (see page 24).

The settings “Push to mute” and “Push to talk” are only available in conjunction with the RMS 1 external mute switch (see page 24 and “Accessories and spare parts” on page 31).

13