Sharp AE-X09NCJ Installation of Indoor Unit con’t, Connecting Indoor and Outdoor Electric Wires

Models: AE-X12NCJ AE-X28NCJ AE-X09NCJ AE-X18NCJ AE-X24NCJ AY-X18NCJ AY-X09NCJ AY-X12NCJ AY-X24NCJ AY-X28NCJ

1 28
Download 28 pages 54.84 Kb
Page 17
Image 17
Installation of Indoor Unit con’t

Installation of Indoor Unit con’t

Connecting Indoor and Outdoor Electric Wires

(1)Open the front panel.

(2)Remove the wiring cover connect and fix power connection cord to the terminal board as shown in Fig 6.

(3)Make the power connection cord pass through the hole at the back of indoor unit.

(4)Reinstall the cord anchorage and wiring cover.

(5)Reinstall the front panel.

Note: AYX09NCJ and AYX12NCJ indoor units may be supplied with 3 pin power cable.

Note: All wires between indoor and outdoor units must be connected by a qualified electrical contractor.

Electric wires must be connected correctly. Improper connection may cause malfunction.

Tighten the terminal screws firmly.

After tightening the screws, pull the wire slightly to confirm whether it's firm or not.

Make sure that connections are earthed and grounded properly to prevent electric shock.

Make sure that all wiring connections are secure and the cover plates are reinstalled properly. Poor installation may cause fire or electric shock.

The piping can be output from right, right rear, left or left rear.

(1)When routing the piping and wiring from the left or right side of indoor unit, cut off the tailings from the chassis when necessary (As shown in Fig.7).

(i)Cut off the tailings 1 when routing the wiring only;

(ii)Cut off the tailings 1 and tailings 2 when routing both the wiring and piping.

(2)Take out the piping from body case, wrap the piping, power cords, drain hose with the tape and then make them pass through the piping hole. (As shown in Fig.8)

(3)Hang the mounting slots of the indoor unit on the upper hooks of the mounting plate and check if it is firm enough. (As shown in Fig.9)

(4)The installation site should be 250cm or more above the floor.

Installation of Connection Pipe

(1)Align the centre of the piping flare with the related valve.

(2)Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench by referring to the following:

Hex nut diameter

Tightening torque (N-m)

Ф 6

1520

Ф 9.52

3040

Ф 12

4555

Ф 16

6065

Ф 19

7075

Note: Connect the connection pipe to indoor unit at first and then to

outdoor unit. Handle pipe bending with care. Do not damage the connection pipe. Ensure that the tapered nut is tightened firmly, otherwise, it may cause leakage.

17