Sharp AY-X12NCJ Operation Tips, Notices for Use, Operating Temperature Range, Cooling Operation

Models: AE-X12NCJ AE-X28NCJ AE-X09NCJ AE-X18NCJ AE-X24NCJ AY-X18NCJ AY-X09NCJ AY-X12NCJ AY-X24NCJ AY-X28NCJ

1 28
Download 28 pages 54.84 Kb
Page 12
Image 12
Operation Tips

Operation Tips

Operating Temperature Range

 

Indoor side DB/WB (°C)

Outdoor side DB/WB (°C)

Maximum cooling

32

43

Maximum cooling

21

21

Maximum heating

27

24

Maximum heating

20

-5

The operating temperature range (outdoor temperature) is 15°C ~ 24°C.

Tips for energy saving:

(1)Do not overcool or overheat.

Setting temperature at a moderate level helps energy saving.

(2)Cover windows with a blind or a curtain.

Blocking sunlight and air from outdoors is favourable for cooling (heating).

(3)Clean air filters once per two weeks.

Clogged air filters lead to inefficient operation and energy waste.

Tips for relative humidity:

(1)Condensate water is likely to form at the air outlet if cooling or drying for a long time when the relative humidity is more the 80% (with doors and windows open).

Notices for Use

Cooling Operation

Principle:

(1)Air conditioners absorb heat in the room and transmit it to the outdoor unit, so that the room temperature is decreased. The cooling capacity will increase or decrease according to outdoor ambient temperature.

Anti freezing Function:

(2)If the unit is operating in COOL mode and in low ambient temperature, frost may be formed on the heat exchanger. When indoor heat exchanger temperature decreased below zero, compressor will stop operation to protect the unit.

Heating Operation

Principle:

(1)Air conditioners absorb heat from outdoors and transmit it to the indoor unit, increasing room temperature. The heating capacity will decrease at low ambient temperature.

Defrosting:

(1)When the outdoor temperature is low but humidity is high, frost may form on the outdoor unit during extended operation, affecting heating efficiency. The air conditioner may stop operation during auto defrosting operation.

(2)During auto defrosting, the fan motors of indoor unit and outdoor unit will stop.

(3)During defrosting, the indoor indicator flashes and the outdoor unit may emit vapour. This is not a malfunction.

(4)After defrosting is finished, the heating operation will recover automatically.

Anti-cold Air Function

In HEAT mode, the indoor fan will not operate in order to prevent cold air blowing out (within 2 minutes) if indoor heat exchanger doesn’t reach a certain temperature under the following three states:

(1)Heating operation starts;

(2)After Auto Defrosting is finished;

(3)Heating at low temperature.

Rest Heat Blow

In the following situations, the indoor unit may still run for some time, to blow out the heat remaining in the indoor unit.

(1)In HEAT mode, the temperature reached the setting value, the compressor stops and the indoor fan still run for 60s.

(2)In HEAT mode, if you turn off the unit, the compressor stops and the indoor fan still runs for 10s.

12

Page 12
Image 12
Sharp AY-X12NCJ Operation Tips, Notices for Use, Operating Temperature Range, Tips for energy saving, Cooling Operation