Mounting using Clamps on Long Edge of Module (Figure 7) – 2 Clamp Method

The modules may be mounted using clamps designed for solar modules as shown in Figure 7. Note the clamp position is important. The 22” length clamp should be positioned so that it supports the center of each long frame of the solar module. The clamp should be affixed to the modules and mounting structure with 4 bolts on each long frame. For the 2 clamp mount method, the minimum clamp length dimension is 22”. The modules should be inserted fully into the module clamps so that the outside edge of the module frame is flush with the inside surface of the clamp. The clamp is designed to overhang the top module edge by 12mm. This mounting method is designed to allow module loading of 1,440 Pa.

C) ELECTRICAL INFORMATION

ELECTRICAL RATINGS

Rated electrical characteristics are within ±10 percent of the indicated values of Isc, Voc and within +5/-0 percent of Pmax under Standard Test Conditions (irradiance of 100 mW/cm2, AM 1.5 spectrum, and a cell temperature of 25˚C (77˚F)). The warranty conditions are specified elsewhere in this manual.

 

ND-255QCS

ND-250QCS

ND-245QCS

Maximum Power (Pmax)

255.0 W

250.0 W

245.0 W

Open-Circuit Voltage (Voc)

38.6 V

38.3 V

37.8 V

Short-Circuit Current (Isc)

9.0 A

8.9 A

8.9 A

Voltage at maximum power (Vpmax)

30.2 V

29.8 V

29.3 V

Current at maximum power (Ipmax)

8.45 A

8.4 A

8.36 A

Maximum System Voltage

600 V

600 V

600 V

Minimum Blocking diode

15 A

15 A

15 A

Series Fuse

15 A

15 A

15 A

 

ND-250QCJ

ND-245QCJ

ND-240QCJ

Maximum Power (Pmax)

250.0 W

245.0 W

240.0 W

Open-Circuit Voltage (Voc)

38.3 V

37.8 V

37.5 V

Short-Circuit Current (Isc)

8.9 A

8.90 A

8.75 A

Voltage at maximum power (Vpmax)

29.8 V

29.3 V

29.3 V

Current at maximum power (Ipmax)

8.4 A

8.36 A

8.19 A

Maximum System Voltage

600 V

600 V

600 V

Minimum Blocking diode

15 A

15 A

15 A

Series Fuse

15 A

15 A

15 A

 

ND-Q250F7

ND-Q245F7

Maximum Power (Pmax)

250.0 W

245.0 W

Open-Circuit Voltage (Voc)

38.3 V

37.8 V

Short-Circuit Current (Isc)

8.9 A

8.9 A

Voltage at maximum power (Vpmax)

29.8 V

29.3 V

Current at maximum power (Ipmax)

8.40 A

8.36 A

Maximum System Voltage

600 V

600 V

Minimum Blocking diode

15 A

15 A

Series Fuse

15 A

15 A

Under normal conditions, a PV module may produce more current and/or voltage than reported at Standard Test Conditions. Accordingly, the values of Isc and Voc marked on UL 1703 listed modules should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor ampacities, fuse sizes and size of controls connected to the module output. Refer to Sec. 690-8 of the National Electrical Code for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable. Where Canadian UL listing applies, installation shall be in accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1.

- 6 -

Installation Manual for PV Modules

Page 6
Image 6