Initialization (Reset)/Functional Restriction Setting

You can return the settings to their factory-preset values and restrict operations.

1.After pressing SIZE for about 5 seconds, press , , , and in that order.

 

 

FUNCTION

1/1

 

 

 

 

 

 

 

 

 

 

ALL RESET

 

 

 

 

 

 

ADJUSTMENT LOCK

OFF

 

 

 

 

OSD DISPLAY

ON

 

 

 

 

LED

ON

 

 

 

 

RS-232C

UNLOCKED

 

 

 

 

 

 

END[MENU]

 

2. Select and set the items.

 

 

 

ALL RESET

 

 

Resets the settings to the factory default settings.

Press , select “ON” and then press MENU .

After initialization, turn the main power switch off and then back on.

ADJUSTMENT LOCK

You can disable operations on the monitor and the remote control unit that use buttons.

OFF ...Enables operation.

1 ........Disables all operations other than turning power

on/off and FUNCTION.

2 ........Only the FUNCTION operation is enabled.

Disables all operations other than FUNCTION (not even power on/off).

OSD DISPLAY

Hides/shows menus.

The FUNCTION screen cannot be hidden.

ON ...........

Displays the menus.

OFF .........

Hides the menus.

LED

Specifies whether to light power LEDs.

ON ...........

Lights power LEDs.

OFF .........

Does not light power LEDs.

RS-232C

Specifies whether to allow control via RS-232C (see

page 25).

 

LOCKED.............

Disables control via RS-232C.

UNLOCKED........

Enables control via RS-232C.

3. Press MENU to return to the normal screen.