Controlling the Monitor with a PC (LAN)

When the PN-ZB01 (optional) is attached, your monitor can be connected to a LAN allowing you to control it from a PC on the LAN.

You can also configure the monitor to send e-mail notification when it has a problem.

The connection requires a commercially available LAN cable (UTP cable, Category 5, straight through).

Network (LAN)

LAN terminal Hub

LAN cable (commercially available, straight)

TIPS

You must assign an IP address to the monitor by following the procedures in “Settings to connect to a LAN”. (See the description on the right.)

Your PC must be installed with Internet Explorer (version 7.0 or later).

To control the monitor via LAN, set RS-232C/LAN SELECT to LAN. (See page 22.)

You cannot use RS-232C and LAN control simultaneously.

Initializing personal information

When the PN-ZB01 (optional) is attached, personal information such as e-mail addresses can be registered in the monitor. Before transferring or disposing of the monitor, initialize all settings by selecting ALL RESET 1. (See page 28.) Note that ALL RESET 2 will not initialize e-mail addresses and other settings.

Settings to connect to a LAN

Set the monitor’s IP address and subnet mask to match the settings of your LAN.

These settings can be made on either the monitor or a PC connected to the monitor.

The settings depend on the configuration of your LAN. Ask your LAN administrator for details.

■ To set on the monitor

Set RS-232C/LAN SELECT on the SETUP menu to LAN, and then set the LAN SETUP options. (See page 22.)

After setting each item, select SET and press MENU .

DHCP CLIENT

If your LAN has a DHCP server and you wish to obtain an address automatically, change this setting to ON.

To set the address manually, set this to OFF.

IP ADDRESS

If the DHCP CLIENT is set to OFF, specify an IP address.

Press or to select items, and press or to change the values.

SUBNET MASK

If the DHCP CLIENT is set to OFF, specify the subnet mask.

Press or to select items, and press or to change the values.

DEFAULT GATEWAY

If the DHCP CLIENT is set to OFF, specify the default gateway.

If you are not using a gateway, specify “0.0.0.0”.

Press or to select items, and press or to change the values.

RESET

Resets the values of the LAN settings to the factory preset values.

Select ON and then press MENU .

TIPS

When the IP address is set manually, the IP addresses of the monitor connected to the RS-232C output terminal and the daisy chain of connected monitors that follows can be assigned automatically. (See page 22.)

41 E

Page 41
Image 41
Sharp PNE802, PN-E802 Controlling the Monitor with a PC LAN, 41 E, Settings to connect to a LAN, To set on the monitor

PNE802, PN-E802 specifications

The Sharp PN-E802 and its variant, PNE802, represent the pinnacle of professional display technology, designed to meet the demanding needs of various commercial environments. With a massive 80-inch diagonal screen, these displays offer an immersive visual experience, making them ideal for use in meeting rooms, conference halls, retail spaces, and control rooms.

One of the key features of the Sharp PN-E802 is its 4K Ultra HD resolution, providing stunning clarity and detail. With a resolution of 3840 x 2160 pixels, images and text appear razor-sharp, allowing viewers to see every detail, which is essential for presentations and video content. The widescreen aspect ratio enhances the cinematic experience, ideal for videos and detailed graphics.

Equipped with advanced LCD technology, the PN-E802 showcases vibrant colors and deep blacks, further enhanced by Sharp's proprietary UV2A technology. This technology improves color accuracy and enhances brightness, ensuring that images remain vivid even in well-lit environments. The display supports a wide color gamut, encompassing a broader range of colors to produce more accurate and lifelike images.

Moreover, the PN-E802 boasts an integrated digital signage function, making it suitable for dynamic content displays. Users can easily manage and update content via a USB connection, allowing for seamless integration into existing systems. This feature is particularly useful for businesses that need to display rotating advertisements or informational content.

Another noteworthy characteristic of the Sharp PN-E802 is its robust build and reliability. Designed for 24/7 operation, this display can withstand constant use without compromising performance. It also features a sleek design, making it an aesthetic addition to any corporate or public space.

Finally, connectivity options abound with the PN-E802, including multiple HDMI, DisplayPort, and DVI inputs, allowing for a versatile array of connection types. This ensures compatibility with various devices, from computers to media players, making installation and integration into existing AV systems straightforward.

In summary, the Sharp PN-E802 and PNE802 models are high-performance displays that combine advanced technology, exceptional image quality, and versatile functionality, making them an excellent choice for any professional setting. Whether for presentations, signage, or collaborative work, these displays deliver an unparalleled viewing experience that stands out in any environment.