Reset procedure if trouble occurs

Exposure to a strong physical shock or powerful electrical fields may render the keys inoperable, to the point that the power cannot be switched on. If such case is suspected, try following the procedure below.

Reset procedures

1.Press the RESET switch located on the bottom of the unit, with the tip of a ball-point pen or similar object. Do not use an object with a breakable or

sharp tip.

The message ‘Do you want to initialize?’ appears.

2.Press Yto initialize the unit.

A message ‘Initialized!’ is momentarily displayed, followed by the LCD contrast adjustment screen.

If Nis selected, then the unit will not be initialized.

3.Follow the instructions on the screen to adjust the LCD contrast, as well as to set the key sound on/off configuration (see steps 7 through 8 of the procedure on page 2.)

Note:

The reset procedure will clear the History list, Calculator's memory, and configuration of the Currency converter, as well as to reset the Set-up menu configuration. To avoid these, you may press Nat step two of the above.

Occasionally when corruption of data etc. occurs, the reset procedure may automatically be initiated upon pressing of the RESET switch or the o key. When this occurs, the message ‘Initialized!’ will be displayed, followed by the LCD contrast screen. Follow the instructions on the LCD contrast, as well as to set the key sound on/off configuration.

Specifications

Model:

PW-E500

Product name:

Electronic Dictionary

Display:

159 80 dot matrix LCD

Number of entries:

• Oxford Dictionary of English:

 

Approx. 355,000 words, phrases, and definitions

 

• New Oxford Thesaurus of English:

 

Approx. 600,000 alternative and opposite words

 

• Oxford Dictionary of Quotations:

 

Approx. 20,000 quotations, comprehensively indexed

 

Approx. 3,200 authors

Calculator function:

12-digit calculation of addition, subtraction,

 

multiplication, division, percentage, memory

 

calculation, etc.

Converter function:

12-digit conversion of currency and measurement

Power consumption:

0.11 W

Operating temperature:

0°C - 40°C (32°F - 104°F)

Power supply:

1.5 V …(DC): Alkaline battery LR03 (size “AAA”) 1

Battery life:

Approx. 200 hours

 

If data is continuously displayed at 25°C (77°F)

Note: May vary according to various usage conditions

Weight (including battery): Approx. 148 g (0.33 lb)

Dimensions (when closed): 125 mm (W) 79.4 mm (D) 16.8 mm (H) 4-29/32" (W) 3-1/8" (D) 21/32" (H)

Accessories:Alkaline battery LR03 (size “AAA”) 1, operation manual