9. Flow Chart of Troubleshooting

9-1. Power On

'Power On ' does not work

Yes

Check the Battery Voltage

is more than 3.5V

Yes

U400 PIN57(PS_HOLD) = 2.6V?

Yes

Check the Clock at

OSC400=32.768KHZ?

Yes

L401(VREG_MSMC) =1.2V?

Yes

L401(VREG_MSME) = 1.8V?

C418(VREG_MSMP) = 2.6V?

C416(VREG_MSMA) = 2.6V?

C408(VREG_TCXO) = 2.8V?

Yes

Check for the clock at

C404= 19.2 MHz

Yes

Check the initial operation

Yes

END

No

No

No

No

No

No

Change the Battery

Check the PMU related to PS_HOLD

Resolder OSC400

Check the PMIC

Check the PMIC

Check the clock generation circuit

(OSC200)