Flow Chart of Troubleshooting

9-19. PCS Transmitter

TX ON (0 Level)

Yes

R120

No

>= -5dBmCheck U100

Yes

No

F100 pin14

>= 25dBm Resolder PAM100

Yes

No

C105Resolder F100 >= 25dBm

Yes

Check UCP300(MSM)

END

9-35

SAMSUNG Proprietary-Contents may change without notice