Stopping the Engine
1.Move throttle lever (D) towards engine to idle position and allow engine to return to idle before shut- ting engine off.
2.Push the red ignition switch until the engine completely stops. See Fig- ure 8.
Figure 8
Operation
Operating Tips for Maximum Performance
Ignition Switch
1. | Minimize friction by using the |
| correct 1.0" ID suction and |
| discharge hoses specified, with a |
| minimum of connections. Keep all |
| hose runs as short as possible. |
2. | Keep the suction head (vertical |
| lift) as short as possible. Do not |
| exceed the pump’s maximum |
| suction head of 26 feet. |
3. | Avoid air leaks. |
| a. All |
| must be tightly secured. |
| b. Make sure the filler cap and |
| drain plug on the pump housing |
WARNING!
■■Keep all pets and bystanders away from the pump during opera- tion and fueling.
■■Beware the pump may shift sud- denly during operation, especially when the hoses first fill with water.
■■Do not wear loose clothing, jew- elry, or long hair that could get caught in machinery.
■■Always wear eye protection such as goggles or safety glasses.
■■Always wear
■■Wear appropriate footwear such as nonskid boots or shoes. Steel- toed rubber boots are strongly recommended. NEVER WORK BAREFOOT!
■■Gloves are recommended.
are tight and free from leakage. |
3.Protect the discharge hose from
4.Abrasive debris can damage the pump impeller and seals, and should be avoided.
5.To minimize clogging the strainer when pumping near mud or debris, place the strainer in a bucket or on a bed of stones.
CAUTION!
Sudden pressure increases (such as from vehicles driving on the discharge hose) can split the discharge hose and may also damage the pump body.
| 50 | |
(meters) | 45 | |
40 | ||
| ||
| 35 | |
| 30 | |
head | 25 | |
20 | ||
| ||
Total | 15 | |
10 | ||
| ||
| 5 | |
| 0 | |
Figure 11 |
The higher the lift, the less the discharge quantity.
50 | 100 | 150 | 200 | 250 | 300 |
Discharge Quantity ( liters per minute)
Keep the suction lift distance as short as possible.
Minimize clogging from debris: Place the suction strainer on a bed of stones or tied in a bucket.
Figure 12
Be careful when locating the pump; the pump may shift suddenly during operation!
Protect the discharge hose
from crushing.