SPECIFICATIONS

Cartridge Type

Permanently Biased Condenser

 

 

Frequency Response

20–20,000 Hz (see Figures 3 and 5)

 

 

Directional Polar Pattern

Cardioid/Omnidirectional (see Figures 4 and 6)

 

 

Output Impedance

150 (actual)

 

 

Attenuation Switch

0 dB,15 dB, or 25 dB attenuation

 

 

Low Frequency Response Switch

Flat; –6 db/octave below 115 Hz;

 

–18 dB/octave below 80 Hz

 

 

Phantom Power

48 Vdc± 4 Vdc (IEC–268–15/DIN 45 596), positive

 

pins 2 and 3

 

 

Current Drain

4.65 mA typical at 48 Vdc

 

 

Common Mode Rejection

50 dB, 20 Hz to 20 kHz

 

 

Polarity

Positive pressure on diaphragm produces positive

 

voltage on output pin 2 relative to pin 3

 

 

Dimensions and Weight

20 mm (0.8 in.) diameter, 146 mm (5.75 in.) long;

 

156 grams (5.5 oz.) (see Figure 7)

 

 

Sensitivity (typical, at 1000 Hz;

–37 dBV/Pa

1 Pa = 94 dB SPL)

 

 

 

Self–noise (typical, equivalent SPL;

14 dB

A-weighted, IEC 651)

 

 

 

Maximum SPL

145 (160, 170) dB

5000 Wload (Attenuator on)

2500 Wload (Attenuator on)

139 (154, 164) dB

1000 Wload (Attenuator on)

134 (149, 159) dB

 

 

Output Clipping Level*

15 dBV

5000 Wload

2500 Wload

9 dBV

1000 Wload

3 dBV

 

 

Dynamic Range

131 dB

5000 Wload

2500 Wload

125 dB

1000 Wload

120 dB

 

 

Signal to Noise Ratio**

80 dB

 

 

*20 Hz to 20 kHz; THD < 1%. THD of the microphone preamplifier when applied input signal is equivalent to the cartridge output at specified SPL.

**S/N ratio is difference between 94 dB SPL and equivalent SPL of self-noise A-weighted.