Diode Isolation of Logic Controls
Two or more control functions using the same logic pins can be isolated with diodes. In this manner a channel can be muted by an overall group mute switch, or by its own cough button (see Figure
D = 1N4148 OR
GROUP EQUIVALENT
MUTE
Mixer logic may be used with
+
5.1 K | 15 V | |
POWER | ||
| ||
| SUPPLY |
–
M1 M3 M5
COUGH
BUTTONS
LOGIC
GROUND
CMOS
GATES
LOGIC
GROUND
G1 M1
O1
DIODE ISOLATION OF LOGIC CONTROLS
FIGURE 19
External Logic Devices
SCM810 logic levels are directly compatible with TTL and
FIGURE 20
Digital Controls or Microcomputers
The SCM810 logic pins can interface with
VOLTAGE SELECTION
The SCM810 can be internally modified to operate from 230 Vac, 50/60 Hz power.
WARNING: Voltages in this equipment are hazardous to life. No
To change the operating voltage, follow these steps.
1.Disconnect the SCM810 from the AC power source.
2.Remove the eight Phillips head screws securing the top cover.
3.Locate Voltage Selector switch SW903 adjacent to power transformer T901 and, using a screwdriver, turn the center rotor to the 230 V posi- tion.
4.Locate Fuse F901 and remove it. Replace it with a 100 mA, 250 V, time delay fuse for
Fuse part numbers are:
Fuse Type | Shure Part No. | Whitefishes Part |
|
| No. |
|
|
|
100 mA, 250 V | 80C258 | 218.100 |
|
|
|
200 mA, 250 V | 80BC8196 | 239.200 |
|
|
|
5.Replace the power cord with a cord rated for 230 V operation, i.e., an IEC appliance connector on the equipment end and a CEE 7/7 (“Schuko”) mains connector on the other.*
Similarly, the SCM810E can be internally modified to operate from 120 Vac, 50/60 Hz power.
*For systems requiring other mains connectors, obtain a power cord with an IEC 320 type mating connector for connection to the SCM810, and an appropriate plug on the other end for connection to the mains. The supplied cord uses Harmonized IEC Cordage with color coding as follows: Brown = Line, Blue = Neutral, Green/Yellow = Ground
13