Increase Hold Time
In addition to the dip switch SW702 options of 0.4- and
Procedure: Install a 470 kΩ resistor across jumper points X902. Move DIP switch down to
Decrease Hold Time
The hold time can be decreased from the factory preset of 0.4 seconds to 0.3 seconds. (Less than 0.3 seconds is not recommended.)
Procedure: Install a 2 MΩ resistor at jumpers X903.
Remote Control of Link Global/Local,
If desired, these functions can each be remotely controlled with an SPST switch.
Procedure:
1.Solder a wire in the pc board jumper hole adjacent to the desired func- tion (printed on the printed circuit board). These jumpers are located just behind DIP switch SW902.
2.Solder a wire in the pc board jumper hole marked “GND” near switch SW902.
3.Set the desired DIP switch(es) to the Up position.
4.Run the jumper wires to the desired remote location and solder them to an SPST toggle switch. The wires can exit the SCM810 chassis above the DIP switches. Shorting any wire to the Ground wire will set the function(s) to the corresponding switch “down” position.
SHURE Incorporated http://www.shure.com United States, Canada, Latin America, Caribbean: 5800 W. Touhy Avenue, Niles, IL
Phone:
Shure Europe GmbH, Phone:
Shure Asia Limited, Phone:
16