Shure MX300 S ABBILDUNG 11 S FIGURA, MX392/MX393 SCHEMATIC DIAGRAM, STROMLAUFPLAN FUR MX392/MX393

Models: MX300

1 24
Download 24 pages 26.57 Kb
Page 24
Image 24
MX392/MX393 SCHEMATIC DIAGRAM

NOTES;

1. All resistors 1/10W, ±1%, 0805, unless otherwise specified.

2. Electrolytic capacitors shown in F x Volts. All non–polar capacitors in F, ±10%, and 50V or more unless otherwise specified.

3.= AC Voltage

= DC Voltage

= Printed Circuit Ground

= Case Ground

= Logic Ground

= AC Voltage, Mic Muted (J4 Shorted)

= DC Voltage, Mic Muted (J4 Shorted)

(+) and/or (–) indicate AC polarity relative to input test signal.

4. Connect J2 to mic input of a Shure M367 Mixer or equivalent, with

48V phantom power switched on.

MX392/MX393 SCHEMATIC DIAGRAM

SCHEMA DE PRINCIPE MX392/MX393

STROMLAUFPLAN FUR MX392/MX393

DIAGRAMA ESQUEMATICO DEL MX392/MX393

SCHEMA CIRCUITALE DEI MODELLI MX392/MX393

FIGURE 11 S ABBILDUNG 11 S FIGURA 11

24

SHURE Incorporated Web Address: http://www.shure.com 222 Hartrey Avenue, Evanston, IL 60202–3696, U.S.A. Phone: 847-866–2200 Fax: 847-866-2279

In Europe, Phone: 49-7131-72140 Fax: 49-7131-721414

In Asia, Phone: 852-2893-4290 Fax: 852-2893-4055

Elsewhere, Phone: 847-866–2200 Fax: 847-866-2585