Operator Control and Monitoring Devices

Panels — 270 series

SIMATIC OP 270

Function

Displaying and modifying process parameters

Function keys

for direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on function keys.

The function keys can be used directly as PROFIBUS DP input peripherals.

Process display:

-OP 270 6“:

QVGA resolution (320 x 240 pixels), OP 270 10“:

VGA resolution (640 x 480 pixels) with 256 colors for display elements

-Vector graphics (various line-drawn and solid objects)

-Dynamic positioning and dynamic showing/hiding of objects

-Pixel graphics displays, curves and bar displays

-Presentation of up to 8 curves in a curve field;

Curve display with scroll and zoom functions for access to the history and for flexible selection of the period for presentation; read-off line for determining the actual values and display in a table

-Comprehensive image libraries (SIMATIC HMI Symbol Library)

-Graphics objects: Slider, gauge, clock

-Cyclic function processing using timers

Multiplex function for variables

Message system

-administration of status, fault and system messages

-Status and fault messages with message history

-Preconfigured message display, message window and message line

Archiving of messages and process values (on CF Card, optionally over Ethernet)

-Different archive types: short-term archive and sequence archive

-Storage of archive data in standard Windows format (CSV)

-Online evaluation of process value archives through curves

-External evaluation using standard tools (MS Excel and MS Access) is possible

Message log and shift log

Print functions (see "recommended printers")

Language selection

5 online languages, 32 configuration languages incl. Asiatic and Cyrillic character sets

Password protection with 10 levels

Recipe management

-With additional data storage (on CF Card)

-Online/offline processing at the panel

-Storage of recipe data in standard Windows format (CSV)

-External processing using standard tools MS Excel and MS Access is possible

PG functions STATUS/CONTROL VAR in combination with SIMATIC S5 and SIMATIC S7

Display selection from the PLC

supports operator prompting from the PLC

Visual Basic Script, flexibility through the implementation of new functions including linking to ProTool variables (compari- son operations, loops, etc.)

• Help texts

for process diagrams, messages and variables

 

• Mathematical functions

2

• Limit value monitoring

for reliable process control of inputs and outputs

Permanent window

permanent display area for the output of information that is not specific to the particular display (e.g. important process vari- ables, date and time)

Simple maintenance and configuration through

-Backup and restoring the configuration, operating system, data records and firmware on the optional CF Card (Compact Flash Card) or optionally over Ethernet

-Backup and restoring the configuration, operating system, data records and firmware on a PC using ProSave

-Configuration download/upload over

USB/MPI/PROFIBUS DP/RS 232/Ethernet (optional)/modem and CF Card (optional)

-Automatic transfer identification

-Individual contrast settings

-Configuration simulation directly on the configuration com- puter

Import/export of all texts including messages in CSV format for translation using standard word processing programs

Additional functions when configuring with WinCC flexible

Project-specific picture blocks that can be modified centrally

Message system

-Bit messages and analog messages (limit value messages) as well as the Alarm S message frame procedure for SIMATIC S7 and SIMOTION

-Freely-definable message classes (e.g. status/fault messages) for definition of acknowledgment response and display of message events

Language selection:

-Language-dependent texts and graphics

Permanent window expanded by template concept;

-generation of screen templates

User administration (security)

-User-oriented access protection according to requirements of specific sectors

-Authentication by means of user ID and password

-Privileges specific to user groups

Visual Basic Runtime object model

Service functions

(optionally with "WinCC flexible/Sm@rtService")

-E-mail generation

-Remote operation of the SIMATIC HMI system based on Internet explorer

-Web server with status HTML pages and control functions

Client/server functions

(optionally with "WinCC flexible /Sm@rtAccess")

-Remote operation and monitoring of other SIMATIC HMI systems

-Plant-wide scanning of information and archiving of process data

Siemens ST 80 · 2006