Temporary timer to extend the Comfort mode

When Economy mode is active, press operating mode button to tempo-

rarily return to Comfort mode. symbol appears. Press operating mode button again to stop the timer.

You can only extend Comfort mode if parameter P02 = 1. Duration * : P68 = 0...360 min, factory setting = 0 min.

Button lock

Press operating mode button for 3 seconds to lock or unlock the buttons if

manual button lock is configured (parameter P14 = 2).

The thermostat automatically locks the buttons 20 seconds after the last adjustment if "Auto lock" is configured (P14 = 1).

The key symbol indicates locked buttons.

Reminder to clean filters and for external faults

FIL *

This message reminds you to clean your HVAC equipment filters.

 

It is displayed after ………… “fan operating hours” and disappears when the

 

thermostat is set to Protection (

 

 

 

).

 

 

 

AL1 * These messages inform you on external faults *:

AL2 *

AL1 :...………………………

 

AL2 :...………………………………….

Note: Economy mode

The Economy setpoints are factory-set to 15 °C for heating and 30 °C for cooling. Use parameters P11 and P12 to adjust the values.

Important: You can set these setpoints to OFF; the thermostat then is inactive, i.e. no protective heating or cooling function.

Risk of frost!

Commissioning

You can adjust a number of different control parameters to adapt the thermostat to your system and optimize control performance. You can do this during operation either via the buttons on the thermostat or using a commissioning tool.

Control sequence

The thermostat can be used in systems either for heating only or cooling only, manually selection of heating or cooling, or automatic heating / cooling changeover. Depending on the selected application, the relevant modes are available and can be adjusted by commissioning parameter P01 if needed.

The factory setting for 2-pipe application is "Cooling only", and for 4 pipe application "Heating and Cooling"

Recalibrating the sensor

If the room temperature displayed by the thermostat does not agree with the temperature effectively measured (after min 1 hour of operation), the tem- perature sensor can be recalibrated. With parameter P05 the temperature can be adjusted by + or – 0.5 °C up to a maximum of + / - 3 °C.

* Needs to be configured by your HVAC installer

Control parameters

Proceed as follows to change the most important control parameters: (Your HVAC installer can set additional parameters)

+/ – 1. Press the and + buttons simultaneously at least 4 seconds. Release, and within 2 seconds, press + again until "P01" is displayed.

2.Repeatedly press the + or button to select the required parameter.

+ P01 - + P02 -

+ P08 -

+ P13 - + P14 -

End -

 

3171z99

 

 

3.Press + and simultaneously. The current value of the selected parameter begins to flash, allowing you to change the value by repeatedly pressing + or .

4.The next parameter is displayed when you press + and again simultaneously.

5.Repeat steps 2 to 4 to display and change additional parameters,.

6.Press + or until “End” is displayed, and then press + and simultaneously to save the change and exit parameter entry mode.

15 minutes after the last display or setting, all changes are saved and the thermostat leaves parameter setting mode.

Para-

Description

 

Factory setting

Setting range

Adj

meter

 

 

 

P01

Control sequence

 

2-pipe: [0…3]

0

= Heating only

 

 

 

 

1

(Cooling only)

1

= Cooling only

 

 

 

 

 

 

2

= Manual H or C

 

 

 

 

4-pipe: [2…4]

3

= Auto Changeover

 

 

 

 

4

(Heating&Cooling)

4

= Heating & cooling

 

P02

Mode selection by user via operating mode button

1

(Auto **,

1

= Auto **, Protection

 

 

 

 

 

Protection)

2

= Auto **, Comfort, Economy,

 

 

 

 

 

 

 

Protection

 

P04

Selection of °C or °F

 

0

(°C)

0

= °C

 

 

 

 

 

 

1

= °F

 

P05

Sensor calibration

 

0.0 °C

– 3 ... +3 °C

 

P06

Standard temperature display

 

0

(Room temp.)

0

= Room temperature

 

 

 

 

 

 

1

= Setpoint

 

P07

Additional user information

 

0

(no display)

0

= No display

 

 

 

 

 

 

1

= Temp. in °C / °F

 

 

 

 

 

 

2

= Outside temperature (via bus)

 

 

 

 

 

 

3

= Time of day (12h, via bus)

 

 

 

 

 

 

4

= Time of day (24h, via bus)

 

P08

Comfort basic setpoint

 

21 °C

5

... 40 °C

 

P09

Minimum setpoint limitation in Comfort

(WminComf)

5 °C

5

... 40 °C

 

P10

Maximum setpoint limitation in Comfort

(WmaxComf)

35 °C

5

... 40 °C

 

P11

Setpoint of heating in Economy

(WheatEco)

15 °C

OFF, 5 °C…WcoolEco

 

P12

Setpoint of cooling in Economy

(WcoolEco)

30 °C

OFF, WheatEco…40°C

 

P13 ***

Electric heater in cooling mode

 

ON

OFF = disabled

 

 

 

 

 

 

ON = enabled

 

P14

Button lock

 

0

(Disabled)

0

= Disabled

 

 

(Press operating mode button for 3 seconds to lock or unlock

 

 

1

= Auto lock

 

 

 

 

2

= Manual lock

 

 

the buttons)

 

 

 

 

 

 

 

 

 

 

 

** Without time schedule via KNX, Auto is equal to Comfort.

 

 

Please record all changes you make!

***Parameter P13 is only displayed for application "2-pipe with el heater". All temperature settings in increments of 0.5 °C.

The control parameters displayed depend on the DIP switch settings made

CE1B3171.1en / 2012-08-29

Subject to change

Siemens Building Technologies

Page 2
Image 2
Siemens rdf600kn Temporary timer to extend the Comfort mode, Button lock, Commissioning, Control parameters

rdf600kn specifications

The Siemens RDF600KN is a sophisticated and versatile device that caters to the needs of industrial automation and control systems. Designed primarily for remote terminal unit (RTU) applications, the RDF600KN serves a crucial role in monitoring and controlling processes in various industries such as water management, oil and gas, and power generation.

One of the main features of the RDF600KN is its robust communication capabilities. It supports a wide array of communication protocols, including IEC 60870-5-101, IEC 60870-5-104, and Modbus, ensuring seamless integration with diverse systems. This makes it an ideal choice for operators looking to create scalable and flexible control environments. The device is equipped with Ethernet connectivity, allowing for efficient data exchange and real-time access to critical information from remote locations.

The RDF600KN is designed with a high degree of reliability and durability in mind. It boasts an IP65 rating, meaning it can withstand dust, moisture, and harsh environmental conditions. This ruggedness makes it particularly suitable for deployment in outdoor settings or environments with extreme temperatures. Furthermore, it is engineered to operate continuously, ensuring high availability and minimal downtime, which is essential for critical applications.

Another notable characteristic of the RDF600KN is its advanced data processing capabilities. With integrated data logging functions, it can store historical data and event logs, providing valuable insights into system performance and operational trends. This feature aids in maintenance strategies and enhances decision-making processes by enabling predictive maintenance practices.

The device also incorporates advanced security features to safeguard against unauthorized access and cyber threats. It supports comprehensive user access controls and encryption protocols, ensuring that sensitive data remains protected while still being readily accessible to authorized personnel.

In terms of configuration and usability, Siemens has designed the RDF600KN with user-friendly interfaces and intuitive software solutions. The configuration can be easily carried out using standard Windows-based tools, simplifying the setup and maintenance process for technicians and engineers.

In summary, the Siemens RDF600KN is a highly capable RTU designed for demanding industrial applications. With its robust communication capabilities, exceptional durability, advanced data processing functions, and comprehensive security measures, it stands out as a reliable solution for effective monitoring and control in various sectors. Its user-friendly design further enhances its appeal, making it a top choice for professionals looking to optimize their operational performance.