Configuration Tool

7.2General functions

The toolbar of the Configuration Tool provides general functions for the parame- ters and the archive. You can also acknowledge events, and authorize yourself in the Configuration Tool.

Table 7-2

Possible operations and displays in the toolbar of the Configuration Tool

 

 

Field / button

Meaning / instruction

 

 

 

 

 

Loads a parameter assignment/an archive from the local file system

 

 

The file must be in the U600 format (*.u600). The parameter assignment

Open

 

and the archive are loaded from the file when it is opened.

 

 

 

 

Notice

 

 

The currently loaded data (parameter assignment and archive) are

 

 

overwritten.

 

 

 

 

 

Saves a parameter assignment/an archive to a local file system

 

 

The data (parameter assignment and archive) are saved in U600 format

Save

 

(*.u600).

 

 

 

 

 

 

 

IP address of the SICLOCK TC100

 

 

Enter the IP address of the device here.

IP address

 

 

 

 

 

 

 

Connects to a device

 

 

The connection is established to the device with the given IP address.

Connect to device

Disconnects from device

 

 

The connection is terminated.

 

 

Die aufgebaute Verbindung wird getrennt.

Disconnect from device

See also Connect / disconnect online connection (Chapter 7.2.1).

 

 

 

 

 

Enter a password to enable a higher access level

 

 

Password supplied with device: "2222"

Authorization - password

See also Authorization (Chapter 7.2.2).

 

 

 

 

 

Executes authorization with the password entered

Authorize

 

 

 

 

 

 

 

Events currently pending in the device

 

 

In online mode, the events pending in the device are shown (e.g.

Event

 

warnings, alarms, etc.)

 

In offline mode, the display contains no information.

(online connection

required)

 

 

 

 

 

 

 

Acknowledges pending event

 

 

In online mode, an acknowledgment for the pending event is sent to the

Confirm event

device. Provided that it is acknowledgeable, the device deletes the event

from the display. Non-acknowledgeable events (persistent indications)

(online connection

remain in the display.

required)

 

 

 

 

 

 

7-4

Siemens AG 2010 All Rights Reserved

 

SICLOCK® TC100 Operating Instructions

Page 49
Image 49
Siemens TC100 manual General functions

TC100 specifications

The Siemens TC100 is a versatile and innovative device designed for a wide range of industrial applications. This advanced technology combines robust performance with reliability, making it an essential component for various sectors, including manufacturing, process automation, and energy management.

One of the main features of the TC100 is its powerful processing capabilities. Equipped with a state-of-the-art processor, the TC100 delivers exceptional speed and efficiency, enabling complex computations and real-time data processing. This makes it suitable for applications that require fast decision-making and precise control.

The device boasts an impressive range of connectivity options, making it adaptable for integration into existing systems. With support for various industrial communication protocols, such as PROFINET, Ethernet/IP, and Modbus, the TC100 ensures seamless communication between devices, facilitating efficient data exchange and monitoring.

Another significant characteristic of the Siemens TC100 is its robust design. Built to withstand harsh industrial environments, it features an IP65 rating for dust and water protection. This durability ensures that the device can operate effectively in challenging conditions, making it a reliable choice for outdoor installations and environments subjected to vibrations, temperature fluctuations, and moisture.

The TC100 also emphasizes user-friendliness, with a highly intuitive interface that simplifies operation and configuration. The device is equipped with a clear and customizable display, allowing operators to monitor processes in real time and make adjustments as needed. This enhances usability and reduces training time for staff.

In terms of security, the Siemens TC100 incorporates advanced cybersecurity features, protecting sensitive data from unauthorized access. With robust encryption methods and secure communication channels, the device safeguards operations against potential cyber threats, ensuring the integrity of critical industrial systems.

Overall, the Siemens TC100 stands out as a powerful, reliable, and user-friendly solution for diverse industrial applications. Its combination of high-performance processing, extensive connectivity, rugged design, and enhanced security makes it an ideal choice for organizations looking to enhance productivity, improve efficiency, and maintain competitiveness in the market. Whether deployed in manufacturing, logistics, or energy sectors, the TC100 exemplifies Siemens' commitment to innovation and excellence in industrial technology.