2.Since no analog sensor exists and thus no corresponding process value is available, we have to specify the values 'Diameter_tank1' and 'Fill-level_tank1'using the watch table. Create a 'new watch table' and enter the two values. To see the current values, switch 'Monitoring mode on'.

(Controller 001 Watch and force table New watch table Diameter_tank1, Fill-level_tank1

)

3.To specify the values, you have to enter a modify value in the 'Modify value' column. The values are applied in the CPU by clicking the icon 'Modify all selected values once and now'.

(diameter_tank1 = 10.0 fill level_tank1 = 7.0 )