Sierra 215 Specifications Type, Process Connections, Insertion Length, Construction Materials

Models: 215

1 41
Download 41 pages 55.49 Kb
Page 32
Image 32

7.0 SPECIFICATIONS

 

 

TYPE:

Thermal Differential-Dual RTD Sensors

PROCESS CONNECTIONS:

0.75” (19.05mm) MNPT Standard, 0.5"(12.7mm), 1"

 

(25.4mm) MNPT, and various flanges optional.

INSERTION LENGTH:

Two inch (50.8mm) Standard, (shorter 0.5 inch (12.7mm)

 

and longer to 120 inch (3048mm) optional).

CONSTRUCTION MATERIALS:

Wetted parts are 316L SS welded construction (alternate

 

materials for corrosive environments available as

 

options. Consult factory.)

AGENCY INSTRUMENT RATINGS:

CSA Explosion Proof: (CS series) T4A

 

Class I, Group B, C, and D

 

Class II, Group E, F, and G

 

CENELEC/Explosion Proof (CN Series):

 

EEx d IIC T4(Akron Electric Enclosure)

 

EEx d IIB T4(Killark Enclosure)

 

CE: EMC Directive: 89/336/EEC (CE Option)

OPERATING TEMPERATURE:

Process: -70°C to + 200°C (-100°F to +390°F) standard

 

 

(to + 600°C (+1000°F) optional

 

Electronics: -40°C to +60°C (-40°F to +140°F)

PRESSURE RATED:

To 3000 psig (20.4 MPa)

RANGE

Gaseous Mass Flow: 0.1 to 500 fps

 

Liquid Mass Flow: 0.01 to 5 fps

REPEATABILITY:

± 1% of Set Point or ± 1/32 inch (±.8mm)

TIME RESPONSE:

0.5 to 10 seconds no-flow (dry) to flow (wet) and 2 to 60

 

seconds flow (wet) to no-flow (dry) (application

 

dependent)

INPUT POWER:

115 Vac, 50/60HZ standard. (230 Vac, 50/60HZ, 24 Vdc,

 

or 24 Vac

optional); 3.1w. maximum.

 

SIERRA INSTRUMENTS PART NO.

FUSE REQUIREMENTS (F1):

CSA/FM

CENELEC

115 Vac: 1/4 amp

101603

101605

230 Vac: 1/4 amp

101603

101605

24 Vdc: 1/4 amp

101603

101605

OUTPUT:

5A, 250 VAC, DPDT Standard (Optional 10A, 250 Vac

 

SPDT) 5A 30 VDC

STABILITY:

Temperature compensated over entire range.

IM-215 Rev-A.1

Series Innova-Switch™

Page 32 of 42

Page 32
Image 32
Sierra 215 Specifications Type, Process Connections, Insertion Length, Construction Materials, Agency Instrument Ratings