7.0 SPECIFICATIONS |
|
|
TYPE: | Thermal | |
PROCESS CONNECTIONS: | 0.75” (19.05mm) MNPT Standard, 0.5"(12.7mm), 1" | |
| (25.4mm) MNPT, and various flanges optional. | |
INSERTION LENGTH: | Two inch (50.8mm) Standard, (shorter 0.5 inch (12.7mm) | |
| and longer to 120 inch (3048mm) optional). | |
CONSTRUCTION MATERIALS: | Wetted parts are 316L SS welded construction (alternate | |
| materials for corrosive environments available as | |
| options. Consult factory.) | |
AGENCY INSTRUMENT RATINGS: | CSA Explosion Proof: (CS series) T4A | |
| Class I, Group B, C, and D | |
| Class II, Group E, F, and G | |
| CENELEC/Explosion Proof (CN Series): | |
| EEx d IIC T4(Akron Electric Enclosure) | |
| EEx d IIB T4(Killark Enclosure) | |
| CE: EMC Directive: 89/336/EEC (CE Option) | |
OPERATING TEMPERATURE: | Process: | |
|
| (to + 600°C (+1000°F) optional |
| Electronics: | |
PRESSURE RATED: | To 3000 psig (20.4 MPa) | |
RANGE | Gaseous Mass Flow: 0.1 to 500 fps | |
| Liquid Mass Flow: 0.01 to 5 fps | |
REPEATABILITY: | ± 1% of Set Point or ± 1/32 inch (±.8mm) | |
TIME RESPONSE: | 0.5 to 10 seconds | |
| seconds flow (wet) to | |
| dependent) | |
INPUT POWER: | 115 Vac, 50/60HZ standard. (230 Vac, 50/60HZ, 24 Vdc, | |
| or 24 Vac | optional); 3.1w. maximum. |
| SIERRA INSTRUMENTS PART NO. | |
FUSE REQUIREMENTS (F1): | CSA/FM | CENELEC |
115 Vac: 1/4 amp | 101603 | 101605 |
230 Vac: 1/4 amp | 101603 | 101605 |
24 Vdc: 1/4 amp | 101603 | 101605 |
OUTPUT: | 5A, 250 VAC, DPDT Standard (Optional 10A, 250 Vac | |
| SPDT) 5A 30 VDC | |
STABILITY: | Temperature compensated over entire range. |
| Series | Page 32 of 42 |