The Cricket is a radiant heater - so m ost owners place in a frequently used area such as a fam ily room . It is best to select a central location on the first level of the house where heated air can flow naturally by convection to the est of the house. Heated air rises by natural convection to the rest of the house, so you may want to install ceiling vents or use existing ones to heat upper rooms in a m ulti-level house. For large rooms with high ceilings, a ceiling fan switched to blow upwards can help distribute the heat evenly.

W hen you have selected the location for your stove, you m ust make sure that any combustible materials (i.e. walls, furniture, drapes, etc.) are not any closer than the laboratory approved clearances shown in Figure 4.

NEVER USE A BLACK PIPE OR ANY OTHER CHIMNEY CONNECTOR TO PASS THROUGH A WALL.

Do not install a stove in a closet or other small enclosure.

Do not use a flue designed for gas appliance, or “B” vent.

Always maintain the minim um clearances and m inim um floor protection as shown in Figures 4 and 5. Review this inform ation before deciding where to locate the stove and its chim ney. NEVER place your stove closer to walls, drapes, or furniture than the distances shown in Figure 5.

IV. MOBILE HOME INSTALLATION

Your SIERRA 5300 is approved for installation into a

m obile hom e, with the addition of the outside air adapter, Part no 405348. The outside air kit allows com bustion air to be bought into the stove from outside of the house as opposed to taking air from the room .

For space heaters installed in mobile hom es, attach the space heater to the structure. Install in accordance to 224 CFR, part 3280 (HUD)

The outside air adapter consists of a m etal plate with a flange that is attached to the bottom of the stove with two screws. The hom eowner or installer must attach a pipe (4" m inim um ) from this flange through the floor of the mobile home.

Installation: (See Figure 8)

1.Rem ove the two screws from the bottom of your stove.

2.Place an outside air adapter over the opening on the bottom of the stove ad attach with the screws rem oved in Step 1. Make sure the flange of the adapter is on the bottom .

3.The pipe (4" alum inum dryer vent pipe) must be connected to the flange, passed through the stove pedestal and through the floor.

4.Squeeze the end of the pipe to be attached to the outside air adapter to from an oval. Slide the form ed end of the pipe over the flange o the adapter and secure with two m etal screws in holes provided.

5.Make sure to add flashing to the pipe where it passes through the floor and screen over the pipe as a guard against birds, rodents, etc.

6.Make sure your stove is properly fastened to the floor on all four corners.

V. OPERATING INSTRUCTIONS

NOTE: For the first few days, the stove will give off an odor and a small amount of smoke. This happens when the high temperature paint is bonding to the metal. It is normal, will stop when the paint is cured, and will reoccur every time you repaint or touch up the paint on your stove.

1.Crumble three or four full sheets of newspaper and place them on the firebrick floor of your Sierra stove.

2.Crisscross two layers of dry kindling on the paper. Add a few larger splits of dry wood on top of the kindling.

3.Make sure the primary air control is fully open.

4.Light the paper under the kindling with a match or lighter. Do not use gasoline, lighter fluid, charcoal starter, kerosene or any other such fuel to start a fire in a woodstove. You may use any type of woodstove fire starter. See your Sierra dealer.

5.At higher altitudes, or when starting a fire on a very cold chimney, it may be necessary to leave the door cracked open to encourage a hot fire. Never leave your stove unattended with the door unlatched! Never leave the door cracked more than 5-10 minutes.

6.W hen the kindling has been consumed and larger splits are burning well, load the stove to the level you desire, using dry, WELL SEASONED DRY WOOD ( wet wood does not heat well) DO NOT BURN COAL IN THIS UNIT.

7.Once your chimney and stove are warmed up and drawing well, close the air inlets to the desired heat output. W hen the primary air control is set at 1/4", your unit will maintain approximately 7000 BTU output may be achieved for when the primary air is fully opened. Reload when convenient, but always while you still have a good bed of glowing embers.

8.W hen opening the door to reload or poke the fire, crack the door and hesitate just a few seconds before swinging it open. All this is to prevent flashbacks which occur when a very smoky fire suddenly is given a lot of oxygen.

Be sure your electrical cord is not routed in front of or close to the firebox.

NOTE: Every stove-chimney combination functions a little differently. Be patient, and expect the stove to be different in January when its cold outside, than it was in September when it was relatively warm. Once a chimney is warmed up, its draft is a function of how much warmer it is than the air around it. On still mild fall evenings, stoves can appear finicky and difficult, but the very next night, in the midst of a fall storm, act like a completely different stove.

9.Do not use a grate with your SIERRA stove. Build the fire directly on the firebrick. W henever the ashes get one to two inches deep, remove them with a shovel and place them in a metal container with a tight-fitting lid. Assume that there are still hot coals mixed in them for at lest three days. DO NOT place them with the garbage or in the garbage or near anything combustible. The best idea is to leave them outside, three feet away from the house, in a metal container, for three days. ASK YOUR DEALER FOR THE SIERRA ASH HOD.

Fuel and ash door must remain closed when in operation. Fireplace stoves with doors should be operated with the doors fully open or fully closed.

All fueling and ash removal doors must remain closed while stove is in operation.

11