A freestanding installation must be installed with 6" x 24 gauge (m inim um ) stove pipe from the stove flue collar to the thim ble of your chim ney. The crim ped end of each pipe should be toward te stove. On horizontal pipe it should be at least 1" higher where it enters the chim ney than on the end toward the stove. Do not use more than (2) elbows and keep the length of the pipe to a minim um , but m aintain the clearances to com bustibles.

See Figure 4, 5, & 6.

The Cricket may also be installed with a UL listed

m anufactured chim ney. These norm ally attach to the flue collar of the stove ad extend straight up through the ceiling and the roof. Make sure all the manufacturers specifications are followed closely, especially when passing through any com bustible walls, ceilings, or roof. Norm ally, an installation using manufacturer’s chim ney is beyond the expertise of the do-it-yourselfer.

Jacket Installation:

An optional jacket is available for your Cricket which reduces clearances to combustibles to 8" from the sides and rear of the unit.

If you purchased this accessory, it attaches to the stove with the following steps: (See Figure 7)

1.Slide jacket over stove.

2.Bolt jacket on with one screw on either side of unit.

3.Hook top of jacket over lip at front of stove and lay lid back over top of stove.

9