Sierra Monitor Corporation EX250-SEN1 Product Summary, Safety, System configuration general

Models: EX250-SEN1

1 19
Download 19 pages 34.67 Kb
Page 4
Image 4

SAFETY ( continued )

Follow the instructions given below when handling your reduced wiring system. Otherwise a damage or failure to cause a malfunction can result.

Operate the reduced wiring system at the specified voltage.

Reserve space for maintenance.

Do not remove any name plate or label.

Do not drop, hit or apply an excessive shock to the unit.

Follow the specified tightening torque.

Do not apply any excessive force to cables by repeated bending, tensioning or placing a heavy object on the cables.

Connect wires and cables correctly.

Do not perform any wiring work while the power is on.

Do not use the reduced wiring system on the same wiring route as the power line or high voltage line.

Confirm the insulation of wiring.

Perform the power supply wiring by dividing into two lines ---- one is for power supply for output

and the other is for power supply for input and controlling.

Take sufficient measures against noise such as noise filter when incorporating the reduced wiring system into a machine or equipment.

Mount a Waterproof Cap on each unused M12 connector for input/output.

Take sufficient shielding measures when operating the product in any of the following places. ( 1 ) A place where noise due to static electricity etc. is generated

( 2 ) A place of high electric field strength

( 3 ) A place where exposure to radioactivity is possible

( 4 ) A place near power cable

Do not operate the product in a place where there is a source of surge.

Use a surge absorbing element built-in type to directly drive the load that generates surge voltage such as solenoid valve.

Prevent any foreign matter such as remnant of wires from getting inside the product when opening the station number switch protective cover.

Install the reduced wiring system in a place free from vibration and impact.

Operate the product in the specified ambient temperature range.

Do not use in a place to be affected by the radiant heat from a surrounding heat source.

Set the DIP switch by using a sharp-pointed watchmakers screwdriver etc.

Perform the maintenance regularly.

Conduct an appropriate functional inspection after completing the maintenance. Do not use chemicals such as benzin and thinner to clean the product.

Product Summary

System configuration general

Solenoid valve

Output Block

(for high wattage load)

Power Block

Output Block

(for low wattage load)

SI Unit applicable to

EtherNet/IP

Input Block

End Plate

Power supply for Output Block (for high wattage load) 24VDC

Connecting to bus at upper level (EtherNet/IP)

Power supply for output/input and control 24VDC

This system realizes reduced wiring between the input and output equipment by con- necting to EtherNet/IP. EtherNet/IP and the input and output equipment communicates through the SI Unit.

Up to 32 Inputs can be connected to the SI Unit using Input Blocks.

Up to 32 Outputs Note) from combined EX9 Output Blocks and Valve manifolds can be connected to the SI Unit.

Note) The maximum output point is 24 when the Power Block is connected.

4

5

Page 4
Image 4
Sierra Monitor Corporation EX250-SEN1 instruction manual Product Summary, Safety, System configuration general

EX250-SEN1 specifications

Sierra Monitor Corporation's EX250-SEN1 is a next-generation environmental monitoring solution designed to enhance the safety and efficiency of industrial operations. This advanced device excels in its core functionality, providing real-time monitoring and management of gas emissions and other environmental factors.

One of the main features of the EX250-SEN1 is its ability to detect a wide range of hazardous gases, including combustible gases, toxic gases, and oxygen levels. This capability is crucial in industries such as oil and gas, manufacturing, and wastewater treatment, where gas leaks can pose serious safety risks. The device ensures compliance with safety regulations by providing operators with timely alerts and notifications of any hazardous conditions.

The EX250-SEN1 utilizes advanced sensor technology that offers high precision and reliability. Its sensors are capable of rapid response times, allowing for quick detection and intervention in case of gas leaks. Moreover, the sensors have a long lifespan and minimal drift, which reduces the need for frequent recalibration, thereby lowering maintenance costs and downtime.

Another significant technology feature of the EX250-SEN1 is its integrated communication capabilities. It can seamlessly connect with existing industrial control systems and networks, including Modbus, Ethernet, and wireless communication protocols. This connectivity allows for real-time data sharing and integration into broader monitoring systems, enabling operators to analyze trends and make informed decisions.

The EX250-SEN1's user-friendly interface further enhances its usability. It includes a clear display that provides immediate access to key performance indicators and gas concentration levels. Operators can easily navigate through various settings and configurations, making adjustments as needed without extensive training.

Additionally, the device is designed with ruggedness and durability in mind. Built to withstand harsh industrial environments, the EX250-SEN1 is resistant to dust, moisture, and extreme temperatures. This resilience ensures reliable performance in the field, reducing the risk of false readings due to environmental factors.

In summary, the Sierra Monitor Corporation EX250-SEN1 is a cutting-edge environmental monitoring device that combines advanced sensor technology, robust communication capabilities, and user-friendly design. Its comprehensive features make it an ideal solution for industries that require vigilant monitoring of environmental safety, promoting a culture of safety and compliance.