Sierra Monitor Corporation EX250-SEN1 Input wiring Cable wiring, Input connector pin layout

Models: EX250-SEN1

1 19
Download 19 pages 34.67 Kb
Page 12
Image 12

Wiring

Input wiring

Cable wiring

EX250-IE1/2/3

Aligning the key groove with the input connector (socket) of Input Block, plug in the cable (plug).

Tighten the lock nut on cable side by turning it clockwise by hand.

Confirm that the connector does not move.

EX250-IE1/2

EX250-IE3

 

EX250-IE2

 

 

 

 

EX250-IE3

 

 

 

(M12 connector, 5 pin, Socket)

 

(M8 connector, 3 pin, Socket)

1

Power supply (24VDC)

 

 

 

 

1

Power supply (24VDC)

 

Input connector

 

 

 

 

 

 

3

Power supply (0V)

1

 

2

Input No.1

3

Power supply (0V)

1

 

3

5

Ground

 

 

 

4

Input

1

 

Input connector

 

5

 

 

 

4

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input No.0

 

 

4

4

Input connector

 

 

 

 

 

 

 

 

 

1

 

 

1

 

2

Input No.3

 

 

3

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

Input connector

 

 

4

5

3

 

 

 

4

 

 

 

 

 

 

 

3

 

 

 

 

Input No.2

 

 

 

 

 

 

 

 

 

 

 

1

3

 

Be sure to check the specifications of the input signal when wiring the sensor.It may cause the malfunction.Mind the position of the mounting key when selecting the sensor.

NOTE

Input connector pin layout

EX250-IE1

(M12 connector, 5 pin, Socket)

1

Power supply (24VDC)

 

 

 

 

3

Power supply (0V)

1

2

Input No.1

*1

5

Ground

 

 

 

5

 

 

 

 

4

3

Input No.0

 

 

 

 

 

 

Input connector "0"

1

2

NC *2

 

 

 

 

 

 

 

5

 

 

 

 

4

3

 

 

Input connector "1"

*1) Input No.1 is connected

to the pin No.2 of the input connector "0",

2 input signals can be directly input from the input connector "0".

*2) NC : Not connected

Mount a Waterproof Cap on each unused connector of Input Block. The proper use of Waterproof Cap can achieve IP67 Enclosure. (Tightening torque : 0.1Nm for M12) For Waterproof Cap, refer to "Option" (page 32) in this manual.

Correlation between input number and Input Block

The total number of Input and Output Blocks can not exceed 10.

The maximum input point is 32.

IE2

IE3

IE2

 

IE1

SI Unit

11

 

6

3

 

1

13

 

8

5

 

BUS

 

0

 

10

7

2

 

 

 

 

 

 

 

PWR

12

4

1

9

The input number is 1, 2 ...32 from the SI Unit side.

20

21

Page 12
Image 12
Sierra Monitor Corporation EX250-SEN1 Input wiring Cable wiring, Input connector pin layout, EX250-IE1/2/3

EX250-SEN1 specifications

Sierra Monitor Corporation's EX250-SEN1 is a next-generation environmental monitoring solution designed to enhance the safety and efficiency of industrial operations. This advanced device excels in its core functionality, providing real-time monitoring and management of gas emissions and other environmental factors.

One of the main features of the EX250-SEN1 is its ability to detect a wide range of hazardous gases, including combustible gases, toxic gases, and oxygen levels. This capability is crucial in industries such as oil and gas, manufacturing, and wastewater treatment, where gas leaks can pose serious safety risks. The device ensures compliance with safety regulations by providing operators with timely alerts and notifications of any hazardous conditions.

The EX250-SEN1 utilizes advanced sensor technology that offers high precision and reliability. Its sensors are capable of rapid response times, allowing for quick detection and intervention in case of gas leaks. Moreover, the sensors have a long lifespan and minimal drift, which reduces the need for frequent recalibration, thereby lowering maintenance costs and downtime.

Another significant technology feature of the EX250-SEN1 is its integrated communication capabilities. It can seamlessly connect with existing industrial control systems and networks, including Modbus, Ethernet, and wireless communication protocols. This connectivity allows for real-time data sharing and integration into broader monitoring systems, enabling operators to analyze trends and make informed decisions.

The EX250-SEN1's user-friendly interface further enhances its usability. It includes a clear display that provides immediate access to key performance indicators and gas concentration levels. Operators can easily navigate through various settings and configurations, making adjustments as needed without extensive training.

Additionally, the device is designed with ruggedness and durability in mind. Built to withstand harsh industrial environments, the EX250-SEN1 is resistant to dust, moisture, and extreme temperatures. This resilience ensures reliable performance in the field, reducing the risk of false readings due to environmental factors.

In summary, the Sierra Monitor Corporation EX250-SEN1 is a cutting-edge environmental monitoring device that combines advanced sensor technology, robust communication capabilities, and user-friendly design. Its comprehensive features make it an ideal solution for industries that require vigilant monitoring of environmental safety, promoting a culture of safety and compliance.