Figure 18 - Setting logs and lava rock

PLACING LOGS AND LAVA ROCKS Assemble ceramic logs by placing the large base log to the rear of grate assembly (Figure 18). Add front logs with “burned through” features to front left and right. Place lava rocks on center of burner. Stack top logs vertically in center of log stack. Adjust as required to provide realistic flame.

(Warning: If flames get trapped under logs the result will be black soot on logs and front face of fireplace. Take extra care to adjust logs to correct this condition).

Figure 18A- Finished log & rock placement

OPERATING YOUR NEW APPLIANCE

When the appliance is being operated for the first time, allow for a supervised burn of 30 minutes. Then shut the appliance off and let it cool completely before relighting. This allows proper curing time for the logs. (After several hours the logs will discolor slightly, this is normal.)

MAINTENANCE

It is recommended that a competent serviceman perform the following procedures at least annually; WARNING: Any change to this fireplace or its co- mponents can be dangerous. Any safety screen or guard removed from fireplace for servicing must be replaced prior to operating the heater. At the beginning of each heating season, have a qualified technician inspect the

Figure 19 - Control and Ignitor Access

burner and pilot burner area for dust or carbon build-up. This may be removed from the burner or logs with a soft bristle brush. A visual inspection of the pilot burner and main burner flame should be performed to verify proper operation, refer to operating instructions for proper adjustment. Care should be taken when cleaning and handling logs since they become brittle with use. Small heat cracks in the logs do not affect the operation of the log set.

Cleaning Stainless Steel

General cleaning may be accomplished by using a household cleaning solution and warm water. The exterior may be cleaned using the same method. Badly soiled or tarnished areas can be clean using a “scotch brite” pad. Always scrub in same direction of material finish.

Do not use caustic cleaners on fireplace as it may cause damage to control and electric components.

CUSTOMER SERVICE& PARTS

REPLACEMENT:

Parts and accessories may be purchased from your local dealer or directly from Sierra Products, Inc. Orders will be accepted by mail, or you may call your order in Mon- day through Friday from 1:00 p.m. to 5:00 p.m. (Pacific Standard Time) at: (909) 399-3355.

Please, fill in the following information for future reference and warranty verification;

Date of Purchase ____________________20____

Model # ________________

Serial # ___________________________________

TROUBLE SHOOTING

If pilot or main burner will not light:

1)Make certain gas supply is turned "ON.”

2)Make certain all air is bled from system.

3)Make certain you have followed the safety and operating instructions.

4)Call a qualified repair person to inspect the appliance.

5)When high winds are present, as a safety feature the pilot burner will not stay lit. Do not operate in high winds.