Application
If the « emergency » reset is used, it has to be driven by an open collector or an open drain output
(due to the internal pull-up resistor embedded into the WISMO218) as shown in the figure below.
GND
1
2
3
Push button~RESET
Figure 39. Example of ~RESET Pin Connection with Pus h Button Configuration

GND

~RESET

Reset

command T1

Rohm DTC144EE

Figure 40. Example of ~RESET Pin Connection with Tr ansistor Configuration
An open collector or open drain transistor can be used to drive the ~RESET pin. If an open collector is
chosen, the recommended digital transistor to use for T1 is the DT C144EE from ROHM.
Table 38. Reset Commands
Reset Comma nd
~RESET
Opera ting M ode
1
0
Reset activated
0
1
Reset inactive
Note: It is recommended to add a varistor (AVL5M02200) on the ~RESET pin in order to enhance the ESD
immunity.