SIIG B5350 manual Device Configuration submenu, 378/IRQ7

Models: B5350

1 70
Download 70 pages 57.38 Kb
Page 60
Image 60

I/O Device Configuration submenu

You can use this screen to configure I/O Devices.

Feature

Option

Description

 

 

 

Serial port A

Enabled / Disabled

Turn serial port A on or off

Base I/O address

3F8 / 2F8 / 3E8 / 2E8

Set the base I/O address for

 

 

serial port A

Interrupt

IRQ3 / IRQ4

Set the interrupt for serial port A

Serial port B

Enabled / Disabled

Turn serial port B on or off

Base I/O address

3F8 / 2F8 / 3E8 / 2E8

Set the base I/O address for

 

 

serial port B

Interrupt

IRQ3 / IRQ4

Set the interrupt for serial port B

Mode

Normal / IrDA / ASK-

Set the mode for the type of

 

IR

device to be attached to serial

 

 

port B

Parallel Port

Enabled / Disabled

Turn the parallel port on or off

Mode

SPP / EPP / EC

Set the mode for the type of

 

 

device to be attached to the par-

 

 

allel port

Base I/O and Inter-

Disabled

Set the base I/O address and

rupt

378/IRQ7

interrupt for the parallel port

 

278/IRQ5 3BC/IRQ7

 

 

 

 

54

 

Appendix

Page 60
Image 60
SIIG B5350 manual Device Configuration submenu, 378/IRQ7