4.2.Addressing of keyboardCUE-S (serial number CS0174.0129 and above)

The ADDRESS of the keyboardCUE-S can be set in the range 0 to 255. Default keyboard ADDRESS is 0.

The BUTTON_ID transmitted by a panel and BUTTON_LED_ID (tabletop model keyboardCUE-S only) are numbers used in the programming for button and bargraph identification. Both values depend on a button position and it depends on a keyboard ADDRESS too. Both values are calculated according formulas

BUTTON_ ID

= Offset + Button Code

BUTTON_LED_ID

= Offset + Button Code

Offset

= 32 * ADDRESS

The lowest BUTTON_ID is generated by a button in the upper left corner the highest BUTTON_ID is generated by a button in the lower right corner - see example for ADDRESS = 0 on the picture below.

In the table below there is Button ID range for some addresses.

ADDRESS

BUTTON_ID range = BUTTON_LED_ID range

0

1

8

 

 

 

1

33

40

 

 

 

2

65

72

 

 

 

9

289

296

 

 

 

User Manual Small Keyboards