TROUBLESHOOTING

Risk of electrical shock and sudden start.

Disconnect electrical power to pump before attempting to troubleshoot or work on it.

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t

Blown fuse

If blown, replace with fuse of proper size

start or run

Low line voltage

If voltage under recommended minimum, check size of wiring

 

 

from main switch on property. If OK, contact power company.

 

Defective motor

Replace pump

 

Impeller

Remove screen, locate source of binding

 

 

 

Pump operates

Low line voltage

Use only 14 gauge or larger extension cords. Use short extension cords

but delivers little

 

when necessary

or no water

Something caught in impeller

Clean out impeller

 

Small diameter garden hose

Use larger diameter garden hose or 1" flexible pipe. Eliminate any

 

or long discharge line

excess hose. Short hoses work best

 

Check valve installed without

Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump

 

vent hole

discharge & check valve

 

Air lock

Turn off pump for a few seconds, clean out anti-airlock hole and restart pump

 

Coils or bends in hose

Straighten hose

 

 

 

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867