Repair Parts / Troubleshooting | 4 |
5
4
3
2
1
5125 0905
REPAIR PARTS
Key | Part Description | Qty. | Part No. |
1 | Screen | 1 | |
2 | Shield | 1 | |
3 | Impeller | 1 | |
4 | Motor | 1 | ** |
5 | Power Cord | 1 | |
• | Garden Hose Adapter | 1 | |
|
|
|
|
NOTICE: To purchase a check valve, call Customer Service at
**If motor fails, replace entire pump.
• Not Illustrated.
Orient Part Number with | ||||||||||
Hole | ||||||||||
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Tighten 1st
3rd2nd
Assemble Screen and Shield as shown.
TROUBLESHOOTING
Risk of electrical shock and sudden start.
Disconnect electrical power to pump before attempting to troubleshoot or work on it.
SYMPTOM | POSSIBLE CAUSE(S) | CORRECTIVE ACTION |
Pump won’t | Blown fuse | If blown, replace with fuse of proper size |
start or run | Low line voltage | If voltage under recommended minimum, check size of wiring |
|
| from main switch on property. If OK, contact power company. |
| Defective motor | Replace pump |
| Impeller | Remove screen, locate source of binding |
|
|
|
Pump operates | Low line voltage | Use only 14 gauge or larger extension cords. Use short extension cords |
but delivers little |
| when necessary |
or no water | Something caught in impeller | Clean out impeller |
| Small diameter garden hose | Use larger diameter garden hose or 1" flexible pipe. Eliminate any |
| or long discharge line | excess hose. Short hoses work best |
| Check valve installed without | Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump |
| vent hole | discharge & check valve |
| Air lock | Turn off pump for a few seconds, clean out |
| Coils or bends in hose | Straighten hose |
|
|
|
For parts or assistance, call Simer Customer Service at