Sinclair ASH-24CN owner manual Troubleshooting, Phenomenon Trouble Shooting

Models: ASH-24CN

1 31
Download 31 pages 47.7 Kb
Page 18
Image 18

1 7

Troubleshooting

Check the following points before requesting on Service center if the malfunction persist, it saves your time and money.

Phenomenon

Trouble Shooting

Please

Indoor unit does not

Once the air conditioner is stopped, it will not oper-

waitting

 

operate immediately

ate in approximately 3 minutes to protect itself.

 

when the air condi-

 

 

tioner is restarted.

 

 

There’s unusual

This is caused by the odors in the room which have

 

smell blowing from

been breathed into the air conditioner.

 

the outlet after op-

 

 

eration is started.

 

 

S o u n d o f w a t e r

This is caused by the refrigerant flowing inside the

 

flow can be heard

unit.

 

during operation.

 

 

Mist is emitted dur-

Because the air of the room is cooled down rapidly

 

ing cooling operation.

by the cold wind and it looks like the fog.

Creaking noise can

This is caused by the deformation of plastic due to

be heard when start

the change of temperature.

or stop the unit.

 

Air condi -

Has the power been shut down?

tioner does

Is the wiring loose?

not operate

Is the leakage protection switch in operation?

at all.

Is voltage higher than 244V or lower than 198V?

OFF

 

Is TIMER ON in operation?

Cooling (Heating)

Is SET TEMP. suitable?

efficiency is not

Is air inlet or outlet obstructed?

good.

Are air filters dirty?

 

Is indoor fan speed set at low speed?

 

Is there any other heat sourse in your room?

Wireless remote

Is the remote control unit out of effective distance

controller is not

to the indoor unit?

available.

Replace the worn batteries of wireless remote con-

 

troller.

 

Are there any obstructions between the wireless

 

remote controller and the signal receptor?