Check after installation
Check after installation
Items to be checked | Possible | Situation |
|
|
|
Has it been fixed firmly? | The unit may drop, shake or emit noise. |
|
Have you done the refrigerant leakage test? | It may cause insufficient refrigerating capacity. |
|
|
|
|
Is heat insulation sufficient? | It may cause condensation and dripping. |
|
|
|
|
Does the unit drain well? | It may cause condensation and dripping. |
|
|
|
|
Is the voltage in accordance with the rated | It may cause electric |
|
voltage marked on the nameplate? | the part. |
|
|
|
|
Is the electrical wiring and piping connection | It may cause electric |
|
installed correctly and securely? | the part. |
|
|
|
|
Has the unit been connected to a secure earth | It may cause electrical leakage. |
|
connection? |
|
|
Is the power cord specified? | It may cause electric |
|
the part. |
| |
|
| |
|
|
|
Has the inlet and outlet been covered? | It may cause insufficient refrigerating capacity. |
|
|
|
|
Has the length of connection pipes and the | The refrigerant capacity is not accurate. |
|
refrigerant capacity been record? |
|
|