SkyLink HA-300 Page 2 of, Operation, Loss Of Signal Indication, Otherhouseholdalert Sensors, Fcc

Models: HA-300

1 2
Download 2 pages 46.02 Kb
Page 2
Image 2
4. OPERATION

4. OPERATION

There are 3 di￿erent operating modes for the Household Alert® Long Range Receiver.

1)Alert - Beeps when a sensor is activated, corresponding zone LED will also ￿ash.

2)Alarm - Sounds an alarm when a sensor is activated, corresponding zone LED will also ￿ash.

3)O￿ - No audio sound will be emitted when sensor is activated. Zone LED will ￿ash to indicate the activated sensor.

To select the operating mode, place the

slide switch on the side at the desired setting:

OFF - No Audio

ALERT - Alert Mode

ALARM - Alarm Mode

Operation

Alert

When motion is detected in the monitored area, the sensor will send a signal to the receiver. It will beep and the corresponding zone red LED will ￿ash for 15 seconds.

If the sensor is set to zone 1, zone 1 red LED on the receiver will ￿ash, and the receiver will emit a continuous “single beep”, i.e. “beep” pause, “beep”, pause….. etc.

If the sensor is set to zone 4, zone 4 red LED will ￿ash, and the receiver will emit a continuous “4 beeps”, i.e. “beep beep beep beep” pause “beep beep beep beep” pause ……etc.

By the number of beeps emitted by the receiver, user can identify which zone is triggered.

Mute

When a sensor is triggered for a long period of time, you may stop the buzzer by pressing the mute button. When another signal comes again, you can disable the buzzer for all currently activated sensors by pressing

the mute button. The receive will beep again if it receives another signal.

For instance, if you are working in your garage, you may want to disable the buzzer for this garage only. Then you can press the “Mute” button after it starts to sound. If any other sensor is triggered, the receiver will sound again.

Alarm

When the receiver is in Alarm operation mode, it will sound its siren when a sensor is activated. The maximum alarm duration is set for 3 minutes. To terminate the siren during the 3-min interval, press the mute button. Although the alarm siren is terminated, if that sensor is still activated, its corresponding LED will continue to ￿ash.

Note: This audio siren is not intended to prevent intruder break-in, it is rather an alert signal indicating a sensor is activated. Therefore, turning o￿ the siren does not require speci￿c password.

O￿

No audio will be emitted even sensor is activated. Only zone LED will ￿ash.

5. LOSS OF SIGNAL INDICATION

When the battery level on the sensor drops to a certain level, or the sensor is out of the operating range, the receiver will show a “loss of signal” indication. The red LED representing that zone will ￿ash rapidly, i.e. if zone 1 sensor is lost, the zone 1 red LED will ￿ash rapidly.

When the loss of signal indication occurs, move the receiver closer to the corresponding sensor and trigger that sensor. If the red LED stops ￿ash- ing rapidly, that means the receiver or sensor needs to be relocated. If the “loss of signal” indication persists, replace the battery of that sensor.

Page 2 of 2

6.OTHERHOUSEHOLDALERT® SENSORS

The Household Alert ® Long Range Receiver can work with up to 4

di￿erent sensors: garage door monitor sensor, door / window sensor, water sensor, indoor/outdoor motion sensor, etc. Please visit www.skylinkhome.com or contact us at support@skylinkhome.com for more information of how to fully utilize your Wireless Motion Alert.

7. FCC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and

(2)This device must accept any interference received, including interference that may cause undesired operation.

WARNING:

Changes or modi￿cations to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inter- ference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equi pment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment o￿ and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into an outlet on a circuit di￿erent from that to which the receiver is connected.

-Consult the dealer or an experienced radio/TV technician for help.

8. WARRANTY

If, within one year from date of purchase, this product should become defective (except battery), due to faulty workmanship or materials, it will be repaired or replaced, without charge. Proof of purchase and a Return Authorization are required.

9. CUSTOMER SERVICE

If you would like to order Skylink’s products or have di￿culty getting them to work or download information and user manual, please :

1.visit our FAQ section at www.skylinkhome.com, or

2.email us at support@skylinkhome.com, or

3. call our toll free at

1-800-304-1187 from Monday to Friday, 9 am to 5 pm EST.

Fax (800) 286-1320

 

CUSTOMER SERVICE

17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Email:support@skylinkhome.com http://www.skylinkhome.com

P/N.101Z756

©2010 SKYLINK GROUP

Page 2
Image 2
SkyLink HA-300 manual Page 2 of, Operation, Loss Of Signal Indication, Otherhouseholdalert Sensors, Fcc, Warranty