Dimensions

 

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

Consists of

 

 

 

 

Consists of

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of

Module

 

 

 

 

No. of

Module

Size

 

 

A

 

 

 

 

B

 

 

 

C

 

 

D

 

 

 

 

 

 

Dimension

 

 

 

 

 

 

 

 

 

 

 

 

 

Model No.

Dimension

Htg.

Model

 

Model No.

Htg.

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

5712

 

 

7

 

 

20

 

834

 

L

Mod.§

Number

 

L

Mod.§

Number

 

 

5934

 

 

 

 

 

 

2314

1014

 

 

 

 

 

 

GGHT-1875

13'2"

 

5

GG-375HEC

250

 

 

 

8

 

 

 

GGT-400

4'4"

2

GG-200EC

300

 

5934

 

 

8

 

 

2634

12

 

 

GGT-500

4'7"

2

GG-250EC

 

GGHT-2000

13'2"

 

5

GG-399HEC

 

 

 

 

 

 

 

 

GGHT-2100

15'10"

 

6

GG-350HEC

350

 

6618

 

 

9

 

 

30

 

1334

 

GGT-600

4'11"

2

GG-300EC

 

 

 

 

 

 

 

 

 

GGHT-700

5'2"

2

GG-350HEC

 

GGHT-2250

15'10"

 

6

GG-375HEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

375

 

5934

 

 

10

 

 

30

 

1334

 

GGHT-750

5'2"

2

GG-375HEC

 

GGHT-2400

15'10"

 

6

GG-399HEC

399

 

6234

 

 

10

 

 

30

 

1334

 

GGHT-800

5'2"

2

GG-399HEC

 

GGHT-2450

18'6"

 

7

GG-350HEC

 

 

 

 

 

 

 

 

GGHT-2625

18'6"

 

7

GG-375HEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GGT-900

7'7"

3

GG-300C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GGHT-1050

7'10"

3

GG-350HEC

 

GGHT-2800

18'6"

 

7

GG-399HEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GGHT-1125

7'10"

3

GG-375HEC

 

GGHT-2800

21'2"

 

8

GG-350HEC

Design Data

 

 

 

 

 

 

 

 

 

 

 

 

 

GGHT-1200

7'10"

3

GG-399HEC

 

GGHT-3000

21'2"

 

8

GG-375HEC

 

 

 

 

 

 

 

 

 

 

 

 

 

GGT-1200

10'3"

4

GG-300C

 

GGHT-3150

23'10"

 

9

GG-350HEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. ASME

 

 

 

 

 

 

 

 

 

 

 

 

GGHT-1400

10'6"

4

GG-350HEC

 

GGHT-3200

21'2"

 

8

GG-399HEC

 

 

 

 

 

 

 

 

 

 

 

 

GGHT-1500

10'6"

4

GG-375HEC

 

GGHT-3375

23'10"

 

9

GG-375HEC

 

 

Working

 

 

 

 

 

 

 

 

 

 

 

 

GGT-1500

12'11"

5

GG-300EC

 

GGHT-3500

26'6"

 

10

GG-350HEC

 

Pressure: 100 psi

 

 

 

 

 

 

 

 

GGHT-1600

10'6"

4

GG-399HEC

 

GGHT-3600

23'10"

 

10

GG-399HEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GGHT-1750

13'2"

5

GG-350HEC

 

GGHT-3750

26'6"

 

10

GG-375HEC

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GGHT-4000

26'6"

 

10

GG-399HEC

Requirements: 120 volts, 60 Hz,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.34 amps per

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

©Slant/Fin Corp. 2000. Printed in the U.S.A. 1102. Publication No. C-10-MG

SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600

FAX: (516) 484-5921Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario

www.slantfin.com

Page 2
Image 2
Slant/Fin GGT Series dimensions Dimensions, Mod.§

GGT Series specifications

The Slant/Fin GGT Series is a groundbreaking line of high-efficiency condensing gas boilers designed to meet the growing demands for reliability, performance, and energy efficiency in heating systems. One of the standout features of the GGT Series is its advanced condensing technology, which allows for optimal heat extraction from combustion gases. This design significantly enhances efficiency, translating to lower energy bills for homeowners and reduced environmental impact.

A hallmark of the GGT Series is its impressive AFUE (annual fuel utilization efficiency) rating of up to 95%, allowing users to maximize their fuel use while minimizing waste. This efficiency is achieved through a unique design that captures and utilizes heat that would otherwise be lost in traditional boiler systems. The two-stage burner not only provides precise control over heating output but also ensures quieter operation and lower emissions.

The GGT Series is constructed with durable stainless steel heat exchangers, which offer superior resistance to corrosion, leading to a longer lifespan and reduced maintenance needs. The units come equipped with an integrated control system that simplifies user interaction. This advanced control technology allows for easy programming and monitoring, enabling homeowners to manage their heating systems effortlessly. The intuitive interface ensures that users can adjust their heating needs based on personal preferences and comfort levels.

Safety is a top priority for the GGT Series; hence, these boilers are equipped with various safety features, including a high-limit control and flame monitoring system. The units also offer a venting flexibility with options for direct venting or through the roof, making installation adaptable to various home designs and building codes.

Another key characteristic of the GGT Series is its compact design, which allows for easy installation in tight spaces. With models available for both residential and light commercial applications, the GGT Series accommodates a wide range of heating needs, ensuring effective warmth for almost any setting.

In summary, the Slant/Fin GGT Series offers cutting-edge technology, robust construction, and exceptional efficiency, making it an ideal choice for homeowners and businesses looking for a high-performance heating solution. With its combination of advanced features and user-friendly controls, the GGT Series is a sensible and sustainable choice in today’s heating market.