Flow Sensor

Instruction Manual

PFMV5 Series

Thank you for purchasing the SMC PFMV5 Series Flow Sensor.

Please read this manual carefully before operating the flow sensor and make sure you understand the flow sensor, its capabilities and limitations.

Please keep this manual handy for future reference.

URL http://www.smcworld.com

Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

The descriptions of products shown in this document may be used by the other companies as their trademarks.

© 2005 SMC Corporation All Rights Reserved

IMPORTANT MESSAGES

Read this manual and follow its instructions. Signal words such as WARNING, CAUTION and NOTE, will be followed by important safety information that must be carefully reviewed.

Indicates a potentially hazardous situation which could result in death or serious injury if you do not follow instructions.

Indicates a potentially hazardous situation which if not avoided, may result in minor injury or moderate injury.

Gives you helpful information.

Do not disassemble, modify (including change of printed circuit board) or repair.

An injury or failure can result.

Do not operate outside of the specification.

Fire, malfunction or flow sensor damage can result.

Please use it after confirming the specification.

Do not operate in an environment of inflammable, explosive or corrosive gas.

Fire or an explosion can result.

This flow sensor is not an explosion proof type.

To avoid fire and explosion, Do not use the product for flammable fluid.

This flow sensor is designed for air. Only dry air, N2 are applicable.

Do not use this product near by a place where static electricity is a problem.

Otherwise it can cause failure or malfunction of a system.

OPERATOR

This manual has been written for those who have knowledge of machinery and apparatuses that use pneumatic equipment and have full knowledge of assembly, operation and maintenance of such equipment.

Please read this manual carefully and understand it before assembling, operating or providing maintenance service to the flow sensor.

To facilitate recycling, this

 

manual is printed using

This manual is printed in the

biodegradable soy ink, which

"non-water system", which does

can easily be de-inked.

not output toxic liquid waste.

Phone

AUSTRIA / (43) 2262-62 280

ITALY / (39) 02-92711

BELGIUM / (32) 3-355 1464

NETHERLANDS / (31) 20-531 8888

CZECH REP. / (420) 5-414 24611

NORWAY / (47) 67 12 90 20

DENMARK / (45) 70 25 29 00

POLAND / (48) 22-548 50 85

FINLAND / (358) 207 513 513

PORTUGAL / (351) 2 610 89 22

FRANCE / (33) 1-64 76 1000

SPAIN / (34) 945-18 4100

GERMANY / (49) 6103 4020

SWEDEN / (46) 8-603 0700

GREECE / (30) 1- 342 6076

SWITZERLAND / (41) 52-396 3131

HUNGARY / (36) 1-371 1343

TURKEY / (90) 212 221 1512

IRELAND / (353) 1-403 9000 UNITED KINGDOM / (44) 1908-56 3888

Safety Instructions

The Flow Sensor have in after referred to as flow sensor and this manual contain essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.

Please check that you fully understand the definition of the following messages (signs) before going on to read the text, and always follow the instructions.

These instructions must be followed while in maintenance ; Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance.

Otherwise it can cause injury.

Perform proper functional checks and leak tests after maintenance.

Stop operation when an abnormality is observed such that the flow sensor does not work properly or there is a leakage of fluid. Safety is not be assured due to unexpected malfunction. When leakage occurred from other parts except piping, the flow sensor might break. Cut off power supply and stop supplying pressure. Don’t apply pressure at leaking condition.

Precaution on Handling

Use UL approved product for direct current power supply.

1.Clamping voltage current circuit complies with UL508 Circuit which power supply if insulation transducer satisfying following conditions

Max. voltage (No load) : 30Vrms (42.4V peak) or less

Max. current : (1)

8A or less (Including short circuit)

(2)

When limited by the circuit

 

 

protector (fuse etc.) with the ratings in the table

 

 

below.

 

 

Voltage without load (V peak)

Max. current rating (A)

 

 

0 to 20 [V]

5.0

 

 

 

 

Over 20 [V] up to 30 [V]

100/peak voltage

 

 

 

 

2.Circuit (of class 2) which is of 30Vrms (42.4V peak) or less with the power supply unit of class 2 complying with L1310 or transducer of class 2 complying with UL1585.

NOTE

Follow the instructions given below when handling the flow sensor. Otherwise, the flow sensor may be damaged or may fail, thereby resulting in malfunction.

Make sure to use a sensor by the specified voltage.

Make sure to use specified measurement flow and operating pressure.

Page 1
Image 1
SMC Networks PFMV5 instruction manual Safety Instructions, Phone, Otherwise it can cause injury