COMPLIANCES

France and Peru only

This unit cannot be powered from ITsupplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary con- nection point labelled Neutral, connected directly to earth (ground).

Impédance à la terre

Power Cord Set

U.S.A. and Canada

The cord set must be UL-approved and CSA certified.

 

 

 

The minimum specifications for the flexible cord are:

 

- No. 18 AWG - not longer than 2 meters, or 16 AWG.

 

- Type SV or SJ

 

- 3-conductor

 

 

 

The cord set must have a rated current capacity of at least 10 A.

 

 

 

The attachment plug must be an earth-grounding type with NEMA

 

5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.

 

 

Denmark

The supply plug must comply with Section 107-2-D1, Standard

 

DK2-1a or DK2-5a.

 

 

Switzerland

The supply plug must comply with SEV/ASE 1011.

 

 

U.K.

The supply plug must comply with BS1363 (3-pin 13 A) and be fit-

 

ted with a 5 A fuse which complies with BS1362.

 

 

 

The mains cord must be <HAR> or <BASEC> marked and be of

 

type HO3VVF3GO.75 (minimum).

 

 

Europe

The supply plug must comply with CEE7/7 (“SCHUKO”).

 

 

 

The mains cord must be <HAR> or <BASEC> marked and be of

 

type HO3VVF3GO.75 (minimum).

 

 

 

IEC-320 receptacle.

 

 

Veuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch:

AVERTISSEMENT: L’installation et la dépose de ce groupe doivent être confiés à un personnel qualifié.

Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).

vi

Page 10
Image 10
SMC Networks SMCGS24 manual Power Cord Set