CABLES
The table below shows the 10BASE-T/100BASE-TX MDI-X and MDI port pinouts.
Pin | MDI-X Signal Name | MDI Signal Name |
1 | Receive Data plus (RD+) | Transmit Data plus (TD+) |
2 | Receive Data minus (RD-) | Transmit Data minus (TD-) |
3 | Transmit Data plus (TD+) | Receive Data plus (RD+) |
6 | Transmit Data minus (TD-) | Receive Data minus (RD-) |
4,5,7,8 | Not used at 10/100 Mbps | Not used at 10/100 Mbps |
1000BASE-T Pin Assignments
The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports require that all four pairs of wires be connected. Note that for 1000BASE-T operation, all four pairs of wires are used for both transmit and receive.
Use 100-ohm Category 5 or 5e unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
Pin | MDI-X | MDI |
| | |
1 | Bi-directional Data Two Plus (BI_D2+) | Bi-directional Data One Plus (BI_D1+) |
| | |
2 | Bi-directional Data Two Minus (BI_D2-) | Bi-directional Data One Minus (BI_D1-) |
| | |
3 | Bi-directional Data One Plus (BI_D1+) | Bi-directional Data Two Plus (BI_D2+) |
| | |
4 | Bi-directional Data Four Plus (BI_D4+) | Bi-directional Data Three Plus (BI_D3+) |
| | |
5 | Bi-directional Data Four Minus (BI_D4-) | Bi-directional Data Three Minus (BI_D3-) |
| | |
6 | Bi-directional Data One Minus (BI_D1-) | Bi-directional Data Two Minus (BI_D2-) |
| | |
7 | Bi-directional Data Three Plus (BI_D3+) | Bi-directional Data Four Plus (BI_D4+) |
| | |
8 | Bi-directional Data Three Minus (BI_D3-) | Bi-directional Data Four Minus (BI_D4-) |
| | |