Smeg A1C manual Levelling, Instructions for the installer, For operation on 400-415V3N∼ use an

Models: A1C

1 25
Download 25 pages 12.69 Kb
Page 5
Image 5
For operation on 400-415V3N∼: use an

Instructions for the installer

For operation on 400-415V3N: use an

H05RR-F-type five-core cable (5 x 2.5 mm2).

For operation on 400-415V2N: use an

H05RR-F-type four-core cable (4 x 4 mm2).

For operation on 230-240V: use an

H05RR-F-type three-core cable (3 x 6 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

Complete wiring up to power supply with an appropriately rated five-core plug (see data plate) or, in case of operation from a 230Vpower supply, with a three-core plug. Make sure that plug and wall socket are of the same type and are in conformity with regulations in force. Make sure that the appliance is properly earthed. Before powering, check that the power line is properly earthed. Avoid using adapters or shunters.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.

2.2 Levelling

Adjust the four feet so as to set the appliance on a perfectly level plane. For this purpose, loosen the lock nut and unscrew the foot. The range of adjustment of the screw is 10 mm.

32