Smeg A3SX manual Final Operations, 4.1Adjustment of minimum for natural gas

Models: A3SX

1 40
Download 40 pages 19.54 Kb
Page 12
Image 12
4. FINAL OPERATIONS

Instructions for the installer

4. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is in the packet together with the nozzles.

4.1Adjustment of minimum for natural gas

Light the burner and turn it to the minimum position 4.1Adjustment of minimum for natural gas. Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.

Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

4.2Mounting the rear top upstand

Position the upstand above the top, taking care to align holes A with holes B.

Secure the upstand to the top by tightening screws C.

14

Page 12
Image 12
Smeg A3SX manual Final Operations, 4.1Adjustment of minimum for natural gas, 4.2Mounting the rear top upstand