2. INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by authorised persons. Clearance around the cooker must comply with the requirements of AS5601.

2.1 Positioning and levelling of the appliance

This appliance is fitted with 4 castors for easy positioning. To block the appliance in tis final position, extract the feet on the front and screw the corresponding castors in.

CAUTION: delicate floors could be damaged by the castors; in this case, lift the appliance with a mechanical means.

2.2 Electrical connection

Make sure that the power line voltage matches the specifications indicated on the rating plate located inside the storage compartment.

This rating plate must never be removed.

The connection to the mains shall be done conforming to the regulations in force. Check that the power line is adequately grounded. Do not use reducers, adapters or shunts. On the power line, install an omnipolar cut- off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit.

For operation on 400-415V3N: use an H05RR-F-typefive-core cable (5 x 1.5 mm2).

For operation on 400-415V2N: use an H05RR-F-typefour-core cable (4 x 2.5 mm2).

For operation on 230-240V: use an H05RR-F-typethree-core cable (3 x 4 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.