Instructions for the installer

2. OVEN INSTALLATION

The oven must be installed on a free-standing horizontal work top. The distance from the rear wall must allow easy access to the terminal board for connection of the power supply cable. Installation must be carried out by a qualified technician and in compliance with EEC DIRECTIVES currently in force.

2.1Electrical connection

Make sure the voltage and the cross-section of the power cord match the specifications indicated on the identification plate positioned on the side

of the oven. Do not remove this plate for any reason.

The oven is equipped with a three-core H07RN-F cable for operation at 220-240V.

For operation at 380-415V2Nor 380-415V3N, the power supply cable must be changed and the connection to the terminal board must be modified. This is can be accessed by removing the panel located on the back of the oven.

The supplied cable is a H07RN-F 3 x 4 mm2 three-core cable.

For operating at 380-415V2Nor 380-415V3N, the cable must be replaced by a H07RN-F type. The cross-section of the wires of the new

cable must not be less than 2.5-1.5 mm2 (4 x

2.5 mm2 - 5 x 1.5 mm2), remembering that the end to be connected to the oven must have an earth cable (yellow-green) that is at least 20 mm longer.

24

Page 4
Image 4
Smeg ALFA141XE, ALFA141VE manual Instructions for the installer, Oven Installation, Electrical connection