Smeg ALFA141XE, ALFA141VE manual Instructions for the installer, 2.4Steam outlet pipe, them

Models: ALFA141VE ALFA141XE

1 17
Download 17 pages 33.18 Kb
Page 6
Image 6
2.4Steam outlet pipe

Instructions for the installer

2.3Connection to the water mains (only in the steam model)

Connect the water inlet socket on the back to a water socket with a threaded

¾gas opening, taking care to screw it

tightly to the hose.

If the water piping is new or has been unused for a long time, before connection, run the water to make sure it becomes clear and free of impurities. Without this precaution, there is a risk that the water inlet will become clogged causing damage to the appliance.

It is recommended to supply the oven with water pressure between: min. 50 kPa and max. 500 kPa.

2.4Steam outlet pipe

Depending on the model, there are two outlet pipes on the back of the oven for releasing the steam produced during cooking. These must be left free of any obstruction. Avoid crushing

them

26

Page 6
Image 6
Smeg ALFA141XE, ALFA141VE manual Instructions for the installer, 2.4Steam outlet pipe, them