2. OVEN INSTALLATION

The oven must be installed on a free-standing horizontal work top. The distance from the rear wall must allow easy access to the terminal board for connection of the power supply cable. Installation must be carried out by a qualified technician and in compliance with EEC DIRECTIVES currently in force.

2.1Electrical connection

Make sure the voltage and the cross-section of the power cord match the specifications indicated on the identification plate positioned on the side of the oven. Do not remove this plate for any reason.

ALFA241

For operation on 380-415V 3N~: use an

H07RN-F type five-core cable (5 x 1.5 mm2).

ALFA341

For operation on 380-415V 3N~: use an

H07RN-F type five-core cable (5 x 4 mm2).

When linking up to mains by plug and socket, the connection must be completed with a plug of adequate capacity. The plug and wall-mounted socket must be of the same type (in accordance with CEI regulations). Make sure that the supply line is suitably earthed. Avoid use of adapters and shunts.

If the appliance is connected to the electrical mains supply in a permanent manner, install a multipolar cut-out device on the line, with contact opening distance equal to or greater than 3 mm located near the appliance and in an easily reachable position.