14. INSTALLATION

14.1 Technical information

Appliance type

See rating plate

 

Electrical connections

220 - 240V~ 50Hz / 220 - 240V 2/ 380 - 415V 2N

Required protection fuse for the oven

30 Amps

 

 

Hob rating

Gas

 

 

Oven rating

Electric

 

 

Maximum electrical power

5.38 kW

 

 

Small oven grilling rating

Electric

 

 

Small grill power

1.85 kW

(230 V)

 

Large grill power

2.65 kW

(230 V)

 

Ovens lightings

25 W

(230 V)

 

OVEN CAVITY DIMENSIONS

Large oven

Small oven

Height (cm)

 

34

17

Width (cm)

 

41

41

Depth (cm)

 

40

41

Internal volume (cm2)

 

55760

28577

14.2 The rating plate

CHECK THAT THE VOLTAGE AND DIMENSIONING

OF THE SUPPLY LINE CORRESPOND TO THE

CHARACTERISTICS SHOWN ON THE PLATE

FIXED TO THE REAR PROTECTIVE COVER OF

THE APPLIANCE.

THIS PLATE MUST NEVER BE REMOVED.

14.3 Electrical connection

IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES.

WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH APPLICABLE REGULATIONS.

THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.

NEVER UNPLUG BY PULLING ON THE CABLE.

IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN, FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.

NEVER ATTEMPT TO REPAIR THE APPLIANCE.

IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS THESE COULD CAUSE OVERHEATING AND RISK OF BURNS.

IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN 3 MM IN AN EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE OVEN.