Smeg CC62MFX5 manual Installation of the appliance, Instructions for the installer

Models: CC62MFX5

1 24
Download 24 pages 10.88 Kb
Page 19
Image 19
14.4 Installation of the appliance

Instructions for the installer

For operation on 220-240 V: use an H05RR-F or H05V2V2-F type three-core cable (3 x 2.5 mm2).

For operation on 220-240 V 3: use an H05RR-F or H05V2V2-F type five-core cable (4 x 1.5 mm2).

For operation on 380-415 V 2N: use an H05RR-F or H05V2V2-F type four-core cable (4 x 1.5 mm2).

The cable end to be connected to the appliance must be provided with an earth wire (yellow-green) at least 20 mm longer.

The manufacturer declines all responsibility for damage to persons or things caused by non- observance of the above prescriptions or by interference with any part of the appliance.

14.4 Installation of the appliance

It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.

It can be placed against walls higher than the hob, at a distance of at least 50 mm from the side of the appliance, as shown in the drawings A and B relating to the installation classes. Wall units or extractor hoods located above the hob must be at least 750 mm away from it.

21

Page 19
Image 19
Smeg CC62MFX5 manual Installation of the appliance, Instructions for the installer