Instructions for the installer

16. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is in the packet together with the nozzles.

16.1 Regulation of the hob burner minimum level for natural gas

Light the burner and turn it to the minimum position . Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.

Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

16.2 Regulation of the hob burner minimum level for LPG

In order to adjust the minimum with LPG, the screw at the side of the tap rod must be turned clockwise all the way.

The bypass diameters for each individual burner are shown in paragraph “15.2 Burner and nozzle characteristics table". Once the regulation has been completed, restore the seal on the by-passes using paint or similar materials.

16.3Mounting the rear top skirtboard

Loosen nuts B.

Position the skirt above the top, taking care to align pins C with holes D.

Secure the skirt to the top by tightening screws A.

ALWAYS INSTALL THE REAR TOP SKIRTBOARD WHICH IS AN INTEGRAL PART OF THE APPLIANCE

16.4Wall fixing

Stretch out the chain attached to the cooker horizontally so that the other end touches the wall.

Mark the wall in the position where the hole is to be drilled.

Drill the hole, insert a wall plug and attach the chain.

Move the cooker up against the wall.

25

Page 23
Image 23
Smeg CC62MFX5 manual Final Operations, Regulation of the hob burner minimum level for natural gas, Wall fixing