Smeg CIR597X manual Instructions for the installer, Regulation for LPG, Burner, ULPG – 2.75 kPa

Models: CIR597X5 CIR597X

1 20
Download 20 pages 2.23 Kb
Page 12
Image 12
5.2 Regulation for LPG

Instructions for the installer

5.2 Regulation for LPG

Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly. Place the burner on its support and ignite it. Move the Venturi tube D to regulate the air flow until the flame is stable and burns regularly, then secure the tube by means of screw A.

 

Burner

 

 

 

ULPG – 2.75 kPa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas consumption

 

 

Injector

 

 

 

 

 

(MJ/h)

 

 

(mm)

 

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

 

 

4.8

 

 

0.60

 

 

 

 

 

 

 

 

 

Semi-rapid (2)

 

 

 

6.0

 

 

0.68

 

 

 

 

 

 

 

 

 

Rapid (3)

 

 

 

12.5

 

 

0.95

 

 

 

 

 

 

 

 

 

 

Double crown

 

internal (4)

 

3.8

 

 

0.48

 

 

 

 

 

 

 

 

 

 

 

external (4)

 

14.4

 

 

0.98

14