Transport instructions

The appliance should be transported only in upright position.

The packing as supplied must be intact during transportation.

f the appliance is transported in the horizontal position, it must be placed vertically and left in this position for 4 hours before taking into operation.

The appliance must be protected against rain, moisture and other atmospheric influences. The manufacturer assumes no liability if safety instructions are disregarded.

Transport instructions Disposal

Make the appliance unusable immediately. Pull out the mains plug and cut the power cable. Remove or destroy snap or latch locks before disposing of the appliance. In this manner you prevent children from locking themselves in and endangering their lives.

Appliance setup

Do not operate your appliance in a room where the temperature is likely to fall below 10 °C at night and/or especially in winter. At lower temperatures the appliance may not operate, resulting in a reduction in the storage life of the food.

The climate class rate of your appliance is given on the rating label located inside the appliance. It specifies the appropriate operating ambient temperatures as explained below.

Climatic class

Ambient temperatures

SN

+10 °C to 32 °C

N

+16 °C to 32 °C

ST

+18 °C to 38 °C

T

+18 °C to 43 °C

SN-ST

+10 °C to 38 °C

SN-T

+10 °C to 43 °C

Location

Only place the appliance in dry rooms which can be ventilated.

Avoid direct sunlight or direct heat sources such as a stove or a heater.

If this cannot be avoided, the following minimum distances should be maintained:

From cookers:

3.00 cm

From heaters:

3.00 cm

From cooling devices:

2.50 cm

Make sure that sufficient room is provided around the appliance to ensure free air circulation.

•Depending on the model of your product, two plastic wall spacers or a back air grille is supplied with your appliance.

If your appliance is equipped with an air grille, please refer (Fig. 2 a) for installation of the air grille.

If your appliance is equipped with two plastic wall spacers, fit the spacers by rotating 1/4 turn to the condenser at the back of the appliance (Fig. 2 b).

The appliance should be located on a level surface. The two front feet can be adjusted as required. To ensure that your appliance is standing upright adjust the two front feet by turning clockwise or counter-clockwise, until the product is in firm contact with the floor. Correct adjustment of feet avoids excessive vibration and noise.

Installation (Under the counter)

Internal height of the counter should be 820mm.

(!) Cookers or other heat sources must not be placed above the counter where the appliance is installed under the counter.

The mains wall socket plug must be close to the right or left hand side of the appliance.

Remove the top cover of the appliance. There are 4 screws(2 pieces at the back, 2 pieces below the front edge) that should be removed.

Fig. 7

Cut the part shown in the picture and then remove it by the help of pliers.

Place you appliance under the counter and adjust the front feets until its top touches to the counter.

In order to use the product under the counter, the distance between the wall and the reference indicated in the top connection plastic must be minimum 595 mm. Fig. 8-9

Fix the appliance under the counter by using

2 of the screws that was removed from the top cover.(Material of the counter must be plastics or wood based!) Fig. 10