5.3Regulation for natural gas
Natural gas – G20 20 mbar

Instructions for the installer

5.3Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph “5.4 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

Rated

Burnerheating capacity

 

 

 

 

 

 

Nozzle diameter

 

Reduced flowrate

 

 

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

Auxiliary

 

 

1.05

 

73

 

380

 

 

 

 

 

 

Semirapid

 

1.65

 

92

 

380

 

 

 

 

 

 

 

Rapid

 

 

2.55

 

115

 

650

 

 

 

 

 

 

Rapid large

 

3.1

 

126

 

750

 

 

 

 

 

 

 

Fish pan

 

 

2.0

 

100

 

750

 

 

 

 

 

 

Ultra rapid

 

3.3

 

130

 

1200

 

 

 

 

 

 

 

Double

 

Internal

 

0.8

 

67

 

380

crown

 

 

 

 

 

 

 

External

 

3.3

 

130

 

1200

5.4Regulation of primary air

Referred to distance “X” in mm.

 

Burner

 

 

 

 

 

 

G20

 

 

 

G30/G31

 

 

 

 

 

 

 

20 mbar

 

 

 

30/37 mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

1.5

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semirapid (2)

 

1.5

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

1.0

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid large (4)

2.5

10.0

 

 

 

 

 

 

 

 

 

 

Fish pan (7)

 

 

2.0

 

2.5

 

 

 

 

 

 

 

 

 

Ultra rapid (5)

 

 

 

2.0

 

2.5

 

 

 

 

 

 

 

 

 

Ultra rapid (8)

 

 

 

2.0

 

2.5

 

 

 

 

 

 

 

 

 

Double

Internal

 

9.0

1.0

 

crown (6)

 

 

 

 

 

 

 

External

 

1.5

8.0

 

 

 

 

 

 

 

 

 

Double

Internal

 

1.5

1.5

 

crown (9)

 

 

 

 

 

 

 

External

 

1.5

4.0

To identify the burners on your hob, refer to the drawings in point “6.3 Arrangement of burners on hob “