Smeg GKCO755 5.2Regulation for LPG, LPG - G30/G31 28/37 mbar, Instructions for the installer

Models: GKC755 GKCO755

1 18
Download 18 pages 63.88 Kb
Page 10
Image 10
5.2Regulation for LPG

Instructions for the installer

5.2Regulation for LPG

Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly.

Move the Venturi tube D to regulate the air flow until distance “X” is reached indicated in the chart in paragraph “5.4 Regulation of primary air” and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

 

 

Rated

 

 

LPG – G30/G31 28/37 mbar

 

Burner

 

heating

 

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

Nozzle

 

Reduced

 

 

 

 

 

 

diameter

By-pass

Flowrate

Flowrate

 

 

 

 

flowrate

 

1/100

1/100 mm

g/h G30

g/h G31

 

(W)

 

 

 

 

 

 

 

 

mm

Auxiliary

 

 

1.05

 

48

 

30 (1)

380

 

 

 

 

 

 

 

 

380

Semirapid

1.65

62

30 (1)

 

 

 

 

 

 

 

 

 

650

Rapid

 

2.55

76

37 (2)

 

 

 

 

 

 

 

 

750

Rapid large

3.1

85

43

 

 

 

 

 

 

 

 

 

750

Fish pan

 

2

67

43 (3)

 

 

 

 

 

 

 

 

1200

Ultra rapid

3.3

87

55 (4)

 

 

 

 

 

 

 

 

 

380

Double

 

Internal

1.15

48

30 (1)

crown

 

 

 

 

 

 

 

 

1200

 

External

3.8

93

55 (4)

7675

120 118

185 182

225 222

145 143

240236

84 82

276 271

(1)= 33 for valveless appliances. (2)= 40 for valveless appliances. (3)= 45 for valveless appliances. (4)= 65 for valveless appliances.