Smeg GKC755, GKCO755 manual 5.3Regulation for natural gas, Instructions for the installer

Models: GKC755 GKCO755

1 18
Download 18 pages 63.88 Kb
Page 11
Image 11
5.3Regulation for natural gas

Instructions for the installer

5.3Regulation for natural gas

The hob has been inspected for G25 (2L 3B/P) at a pressure of 25 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5.4 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

 

 

 

 

 

Rated

Burner

 

 

 

heating

 

 

 

 

 

capacity

 

 

 

 

 

 

Auxiliary

 

 

1.05

 

 

 

 

 

Semirapid

 

1.65

 

 

 

 

 

 

Rapid

 

 

2.7

 

 

 

 

 

Rapid large

 

3.1

 

 

 

 

 

 

Fish pan

 

 

2.15

 

 

 

 

 

Ultra rapid

 

3.3

 

 

 

 

 

 

Double

 

Internal

 

1.05

crown

 

External

 

 

3.9

G25 25 mbar

Nozzle diameter

Reduced flowrate

1/100 mm

(W)

 

380

76

 

380

98

 

650

123

 

750

130

 

750

110

 

1200

135

 

380

76

 

1200

150

31

Page 11