5.2Adjusting for bottled gas

Instructions for the Installer

5.2Adjusting for bottled gas

Undo the screw A and push the support B fully down. Remove the nozzle C with a spanner and fit the suitable one following the instructions in the tables referring to the type of gas to be used. The nozzle must not be tightened with a torque of more than 3 Nm. Return the support B to its original position, so that the nozzle C is perfectly covered.

Regulate the air flow by moving the Venturi pipe D until the distance “X” stated in point "5.5 Adjusting the primary air flow” is obtained and secure it with the screw A. When the adjustments are complete, restore the seals with wax or an equivalent material.

Nominal

BurnerheatBottled gas – G30/G31 30/37 mbar capacity

(kW)

Auxiliary

Semi rapid

Rapid (3)

Rapid (7)

Rapid (6)

Ultra-Rapid

Double Internal Crown (4)

External

Double Internal Crown (8)

External

1.05

1.7

3.5

2.9

3.1

4.2

0.9

3.3

0.9

4.0

Nozzle

By-pass

Reduce

Capacity

Capacity

diameter

mm

d heat

g/h G30

g/h G31

1/100 mm

1/100

capacity

 

 

 

 

(W)

 

 

48

30

400

76

75

62

33

500

124

121

89

50

1050

254

250

80

50

1050

211

207

85

50

1050

225

221

98

65

1600

305

300

45

30

400

62

61

87

55

1200

240

236

45

30

400

62

61

95

55

1200

291

286

5.3 Adjusting for town gas

To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Adjusting for bottle gas”, but choose the nozzles and regulate the primary air for town gas, as shown in the following table and in paragraph “5.5 Adjusting the primary air flow”.

 

 

 

 

 

Nominal

 

 

 

 

 

 

Burner

 

 

heat

 

Town gas – G110 8 mbar

 

 

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

Reduced heat capacity

 

 

 

 

 

 

 

 

diameter

 

(W)

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

 

1.05

 

132

 

400

 

 

 

 

 

 

 

 

 

 

 

Semi rapid

 

 

1.7

 

165

 

500

 

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

 

3.5

 

250

 

900

 

 

 

 

 

 

 

 

 

 

 

Rapid (7)

 

 

2.9

 

230

 

1.05

 

 

 

 

 

 

 

 

 

 

 

Rapid (6)

 

 

3.1

 

240

 

900

 

 

 

 

 

 

 

 

 

 

 

Ultra-Rapid

 

 

4.2

 

300

 

1100

 

 

 

 

 

 

 

 

 

 

Double

 

Internal

 

0.9

 

126

 

400

 

 

Crown (4)

 

 

 

 

 

 

 

 

External

 

3.3

 

250

 

1200

 

 

 

 

 

 

 

 

 

Double

 

Internal

 

0.9

 

126

 

400

 

 

Crown (8)

 

 

 

 

 

 

 

 

External

 

4.0

 

300

 

1200

 

 

 

 

 

27